beautypg.com

Figure 19 removing main pcb, Qc connectors removal, Line section removal – Bird Technologies 4391A User Manual

Page 36: Qc connectors removal line section removal

background image

24

Figure 19 Removing Main PCB

QC Connectors Removal

1.

Remove the eight screws (four on each connector) that secure the connec-
tors to the housing (Figure 20, item 1).

2.

Remove the two “QC” connectors (item 2) by pulling them away from the
line section assembly.

Line Section Removal

1.

Remove the QC connectors (page 24).

2.

Remove the four screws and lock washers that secure line section assembly to
the housing (item 3).

3.

Spread apart the sides of the lower housing assembly far enough to allow
the line section assembly to be removed.

Note: Use minimum pressure when performing this step.