Chapter 5 maintenance, Troubleshooting – Bird Technologies 8650B Series User Manual
Page 27
15
Chapter 5
Maintenance
Troubleshooting
The table below contains troubleshooting information for problems which can
occur during normal operation. Locate the problem, review the possible cause,
and perform the action listed.
.
Problem
Possible Cause
Correction
Transmitter
will not come
on
or
Shuts off
repeatedly.
Insufficient coolant flow.
Check coolant gauge.
Check for blockage in circulatory system.
Check for coolant leaks.
Defective flow switch
Check flow switch.
Defective pump
Check pump.
Overheating
Check for sufficient coolant.
Defective thermoswitch
Check thermoswitch.
Check for excessive room temperature.
Check fans for jamming and grilles for
blockage.
Excessive
reflected
power
Damaged resistor
Check resistance value of RF section.
Contaminated coolant
Drain, flush, and refill coolant system.
See “Flushing the System” on page 18.
Insufficient coolant
Check for coolant leaks and add more
coolant.
Coolant
leaking
Loose connections
Check and tighten all connections.
Worn or cracked tubing
Replace defective tubing.
New or
unusual
noises.
Fans
Check for loose fan blades.
Pump
Check pump for signs of failure.
Circulatory system
Check for any sign of coolant leakage.
Burnt out
resistor
Transmitter not connected
to interlock terminals.
Follow installation procedure. See
“Installation” on page 7.
RF power overload
Reduce power output from transmitter.
Check over-temperature thermo-switch.
Moduload will
not come on.
No line power
Check AC power source and power cord.
Fuses burned out
Replace fuses. Check for cause. See
“Replacing the Fuse” on page 22.
Defective switch
Replace switch. See “Replacing the