beautypg.com

Chapter 5 maintenance, Troubleshooting – Bird Technologies 8650B Series User Manual

Page 27

background image

15

Chapter 5

Maintenance

Troubleshooting

The table below contains troubleshooting information for problems which can

occur during normal operation. Locate the problem, review the possible cause,

and perform the action listed.

.

Problem

Possible Cause

Correction

Transmitter
will not come
on
or
Shuts off
repeatedly.

Insufficient coolant flow.

Check coolant gauge.

Check for blockage in circulatory system.

Check for coolant leaks.

Defective flow switch

Check flow switch.

Defective pump

Check pump.

Overheating

Check for sufficient coolant.

Defective thermoswitch

Check thermoswitch.

Check for excessive room temperature.

Check fans for jamming and grilles for
blockage.

Excessive
reflected
power

Damaged resistor

Check resistance value of RF section.

Contaminated coolant

Drain, flush, and refill coolant system.
See “Flushing the System” on page 18.

Insufficient coolant

Check for coolant leaks and add more
coolant.

Coolant
leaking

Loose connections

Check and tighten all connections.

Worn or cracked tubing

Replace defective tubing.

New or
unusual
noises.

Fans

Check for loose fan blades.

Pump

Check pump for signs of failure.

Circulatory system

Check for any sign of coolant leakage.

Burnt out
resistor

Transmitter not connected
to interlock terminals.

Follow installation procedure. See
“Installation” on page 7
.

RF power overload

Reduce power output from transmitter.

Check over-temperature thermo-switch.

Moduload will
not come on.

No line power

Check AC power source and power cord.

Fuses burned out

Replace fuses. Check for cause. See
“Replacing the Fuse” on page 22
.

Defective switch

Replace switch. See “Replacing the
Water Pressure Switch” on page 21.