Bird 8650 Series Moduload RF Load Resistor
8
AC Line Attachment
The AC power supply may either be 115V or 240V depending on the unit require-
ments. AC line power is supplied to the 3-wire AC panel module socket by means
of the 10 foot (3.05 m) cable and matching socket that is furnished with the equip-
ment. The third wire in the cable, coded green/yellow, is the ground wire.
Note:
For proper protection, if a 3-wire type plug and outlet is not
used, fasten the green/yellow wire at the supply end to a satisfactory
ground.
Before applying AC power to the unit, make sure:
z
Coolant is in the system.
z
Coolant is filled to the correct level.
z
The green/yellow wire at the supply end is properly grounded.
Figure 5 Freezing Point of Ethylene Glycol /Water Mixture °F
CAUTION
Before any RF operation of the load is attempted, the transmitter interlock
and AC line attachment to the equipment must be made. First attach the
transmitter interlock connections to the two binding posts on the front
panel and then connect the power cable.
CAUTION
The 115 VAC or 230 VAC line may be connected, but the AC power must not
be turned on unless coolant is in the system and filled to the correct level.
Damage to the pump will result otherwise.
-80
-60
-40
-20
0
20
40
Te
mper
ature, Degr
ees Fa
hrenhei
t
10 20 30 40 50 60
% Ethylene Glycol
Specifications for ethylene glycol
having: specific gravity 1.125 @
32°F; specific heat .575 @ 68°F