Bird 8650 Series Moduload RF Load Resistor

8

AC Line Attachment

The AC power supply may either be 115V or 240V depending on the unit require-
ments. AC line power is supplied to the 3-wire AC panel module socket by means
of the 10 foot (3.05 m) cable and matching socket that is furnished with the equip-
ment. The third wire in the cable, coded green/yellow, is the ground wire.

Note:

For proper protection, if a 3-wire type plug and outlet is not

used, fasten the green/yellow wire at the supply end to a satisfactory
ground.

Before applying AC power to the unit, make sure:

z

Coolant is in the system.

z

Coolant is filled to the correct level.

z

The green/yellow wire at the supply end is properly grounded.

Figure 5 Freezing Point of Ethylene Glycol /Water Mixture °F

CAUTION

Before any RF operation of the load is attempted, the transmitter interlock

and AC line attachment to the equipment must be made. First attach the

transmitter interlock connections to the two binding posts on the front

panel and then connect the power cable.

CAUTION

The 115 VAC or 230 VAC line may be connected, but the AC power must not

be turned on unless coolant is in the system and filled to the correct level.

Damage to the pump will result otherwise.

-80

-60

-40

-20

0

20

40

Te

mper

ature, Degr

ees Fa

hrenhei

t

10 20 30 40 50 60

% Ethylene Glycol

Specifications for ethylene glycol
having: specific gravity 1.125 @
32°F; specific heat .575 @ 68°F