6. Remove the V-band clamp from

around the front (input) connector as-

sembly by loosening the 10-32 holding

screw sufficiently to slip the band off.

7. Carefully work the RF section assem-

bly loose and lift it straight out of the

resistor tank.

+

Note: There will be some initial resistance as

the O-Ring seal around the rear connector as-

sembly comes loose from the housing.

As the RF section comes out of the

rear connector assembly, the coolant

will start to pour into the container.

Work the RF section loose slowly, so

that the coolant doesn’t splash.

8. Let the coolant drip for a few minutes

to get as much as possible out of the

radiator tank. As the RF section is

raised out of the radiator tank some

coolant will be trapped in the rear end

cylinder. Turn the section over care-

fully to empty it out.

+

Note: An alternate, but much slower, method of

draining the radiator would be to siphon the

coolant out of the thermoswitch hole.

9. Discard the contaminated coolant col-

lected in the container.

10. Replace the RF section assembly mak-

ing sure that it is smoothly and firmly

seated in the rear connector assembly.

11. Replace the V-band on the front con-

nector plate assembly and tighten the

screw.

12. Add clean coolant to the unit. Fill the

unit until the level is about 3-1/4

inches below the thermoswitch hole.

13. Coat the pipe plug or thermoswitch

threads sparingly with pipe sealant.

Do not contaminate the coolant.

21

Maintenance