2. Thread the interlock wires through

the clamp (E) with the washers (F) in-

side and with its threaded fitting in

place.

3. Service the interlock wires with short

tips, use spaghetti sleeves over the

wire ends if needed.

4. Securely solder the interlock leads to

the lugs (G) of the connector base.

+

Note: Be sure that the larger captive clamping

nut (A) is in place over the base plug (D) with

the knurled end outward.

5. Screw on the cover ring (C) first, then

fasten the cable clamp (E) in place,

and tighten the two yoke screws (H)

on the cable. Push the plug back onto

the thermoswitch, and tighten the

captive knurled connecting ring. Do

not attempt to operate the equipment

without the interlock attached.

Blower

Assembly

For field installation of the blower assembly refer to the

blower instruction manual.