Bird Technologies 8329-300 User Manual
Page 28
Preparation:
s
Material: Lint-free cleaning cloth
s
Mild detergent
To clean the unit follow the instructions below.
1. Gently remove loose dirt and grime
using a soft clean cloth dampened
with a mild warm solution of deter-
gent and water.
2. Check the condition of the RF coaxial
connector. If it needs cleaning, clean
the connector with a self-drying con-
tact cleaner that leaves no residue on
the inaccessible portions.
Preventive Maintenance
Measure dc
Resistance
Preparation:
s
Tools: Common hand tools
s
Multimeter with an accuracy of ±1% at 50
ohms.
s
Temperature of the load between 20°C to 25°C
(68°F to 77°F)
Accurate measurement of the dc resistance between the in-
ner and outer conductors of the RF input connector will pro-
vide a good check of the condition of the load resistor.
Checking the dc resistance is simply used to measure a
change in the condition of the resistor over time. The track-
ing of the dc resistance must start before the resistor is first
put into service. Perform the following steps and record the
value for future comparison. Check and record the resis-
tance of the load periodically according to use.
WARNING
Never attempt to disconnect the equipment from the
transmission line while RF power is being applied.
Leaking RF energy is a potential health hazard.
1. Turn off RF power and interlock cir-
cuitry before any electrical disconnec-
tions are made.
2. Disconnect the RF coaxial line.
Bird Model 8329-300 Tenuline Attenuator