beautypg.com

Bird Technologies 8329-300 User Manual

Page 29

background image

3. Connect the multimeter test leads

across the center and outer conductor

of the load resistor. Refer to figure 5.

4. Record the value of the resistance be-

fore the load is put into service. Com-

pare the subsequent values with the

latest reading. If the values vary more

than 2 ohms, this could be an indica-

tion of a failing resistive element.

+

Note: It is recommended that this resistance

check be performed each time the load is to be

used.

RF Connector

Tools Required: Screwdriver

The connector is a “Quick-Change” design which permits

easy interchange with the use of only a screwdriver. For re-

placement, proceed as follows:

1. Remove and retain the four screws

from the corners of the RF connector.

2. Pull the connector straight out of its

socket.

3. Insert the new connector into the mat-

ing connector. Be sure the projecting

center pin on the connector is properly

engaged and seated in the mating

socket, then push it in firmly.

19

Maintenance

Figure 5

Meter Lead

Placement