Ambient Lanc Logger - ALL601 User Manual
Page 14

14
TO SWITCH ON FROM STANDBY
Press ESC for 3 seconds, wakeup window shows
Press ESC to wake up
Press ENT to reenter standby
Note: to enter menu and change settings press ENT with selected tab, press
ESC to return
JOB DESCRIPTION
TCO
. TIMECODE OUT The ALL is used as an accurate timecode source.
The following menus are activated
GEN. Here all aspects of the generator TC can be set
Extern: Jam source
Edit: time userbits
Fps: Framerate
Preset: RTC or start form zero
Offset. Offset of Auxiliary TC out (AUDio)
AUD (ATC) TC output parameters.
TC offset, +-10 frames
TC level -55dB (Mike level) to 0dB (Line level) in 10 steps to suit the
input.
Output Mode, Off, Burst, or Continuous.