H and V Parameter Reference Table For Upconvert Mode

H and V Parameter Reference Table For HD Framesync Mode

External Reference Information

The RH10UC expects the External Reference to be an HD Tri-level sync signal. The
Reference must be consistent with the Output Format selection. If the Output Format
selection is “A” for automatic - the RH10UC will detect the format of the Tri-level sync
input and set the Output Format to the detected format. If no reference is provided, the
RH10UC will lock to the input video.

The External Reference input can come from two different sources on the RH10UC. There
are jumpers on the RH10UC (see figure below) for selecting the external reference source
and for optionally terminating the selected reference source.

W

Set RH10UC To Factory Defaults
To set all values to factory defaults, select Param W, and move
the adjust switch to the right. This will set all parameters in the
system to factory values. After a 5 second inactivity time-out, the
values will be written to flash.

If all the values in the system match the factory defaults, either
through adjustment or by setting them as above, the display for
param W will be “WFAC”. If any of the values are different, the
display for param W will simply be “W”.

Table 5.

Parameter

(Character 1)

Definitions
(Choices are shown in italics)

Output Geometry

@ FR

Min V

Delay

Zero-timed V

Delay

Max V Delay

Min H Delay

Zero-timed

H Delay

Max H Delay

1080i @ 29.97 Hz

-999

0

562

0

1877

2199

1080i @ 25 Hz

-999

0

562

0

2014

2639

720p @ 59.94 Hz

-749

0

740

0

1304

1649

720p @ 50 Hz

-749

0

740

0

1304

1649

Output Geometry

@ FR

Min V

Delay

Zero-timed V

Delay

Max V Delay

Min H Delay

Zero-timed

H Delay

Max H Delay

1080i @ 29.97 Hz

-999

0

5

0

2134

2199

1080i @ 25 Hz

-999

0

5

0

68

2639

1080psf @ 23.98
Hz

-999

0

5

0

2134

2749

720p @ 59.94 Hz

-749

0

5

0

0

1649

720p @ 50 Hz

-749

0

5

0

1100

1979