Analog Output Modules (T3470A)


P D - 6 0 2 5 M a r - 0 6

17

analog output module to the factory for repair or
replacement.

14. Calibration is complete. Unplug the printed circuit board

from the I/O extender module and replace it in its
clamshell housing. Remove all forcing of the analog
outputs from the force table using W

INTERPRET

. Remove

the I/O extender module from the I/O chassis and reinstall
the calibrated module in the I/O chassis.

The module’s red Fault indicator will be on until you
perform a voted reset by pressing the Reset buttons on two
of the Regent processor modules. After the voted reset is
complete, the module’s green Active indicator should turn
on.

Safety Considerations

The analog output module is TÜV certified as non-interfering,
and can be used in a safety system for simplex non-safety

critical outputs.

Specifications

Safetybus Power

0.5 load units

Number of Outputs

Eight

External Power

Voltage:

Current:


24 VDC ±5%
0.5 amps, maximum

Output Range

4 to 20 mA

Data Range

0 to 4095

Resolution

12-bit (1 in 4096)

Accuracy

0.1% of full scale @ 25

°

C

Drift

±50 ppm/

°

C

Load Resistance

0 to 500 ohms

Isolation

2500 volts minimum (field
wiring to control logic)