4.7.7.3 Testing Feedback Registers and Bits
This section describes how to test the feedback registers and bits. Feedback
information provided by the fault, warning, and interlock registers is described in
Appendices A, B, and C. Use the AutoMax Programming Executive software I/O
Monitor function to display the registers and bits in the format listed in table 4.3.
Step 1. Verify that register 200/1200, bit 15 is on. This bit is on when PMI operating
system has been successfully downloaded from the UDC module to the PMI.
Step 2. Check each of the inputs identified by bits 1 through 5 of register 201/1201 by
applying 115V to the appropriate pins on the Drive I/O connector on the
Resolver and Drive I/O module and verifying that the appropriate bit is on.
Refer to the SA500 Power Modules instruction manual (S-3018) for the
pinout description.
Table 4.3 – Feedback Registers and Bits
Drive A/B
Variable Name
Description
200 / 1200
Bit 15
(PMI_OK@)
Drive Status Register
PMI Operating System Loaded
201 / 1201
I/O Status Register
Bit 0
(RPI@)
Run Permissive Input
Bit 1
(M_FDBK@)
M-Contactor Feedback Input or
(AUX_IN1@)
115VAC Auxiliary Input 1
Bit 2
(AUX_IN2@)
115VAC Auxiliary Input 2
Bit 3
(AUX_IN3@)
115VAC Auxiliary Input 3
Bit 4
(AUX_IN4@)
115VAC Auxiliary Input 4
Bit 5
(AUX_IN5@)
115VAC Auxiliary Input 5
Bit 8
(STR_DET@)
External Strobe Detected
203 / 1203
Drive Warning Register
Bit 13
(WRN_RAL@)
Rail I/O Communication Error
206 / 1206
(SPD_FB%)
Speed Feedback (-4095 to +4095)
207 / 1207
(TRQ_FB%)
Torque Feedback (-4095 to +4095)
208 / 1208
(POS_FB%)
Position Feedback (-32768 to +32767)
209 / 1209
(POS_REG_OUT%)
Position Loop Output (-4095 to +4095)
211 / 1211
(I_FBN%)
Current Feedback (normalized) (-4095 to +4095)
213 / 1213
(SPD_ERR%)
Speed Error (-4095 to +4095)
214 / 1214
(USER_AIN%)
Analog Input (-2048 = -10 V to +2047 = +10V)
215 / 1215
(RES_SCN_POS%)
Resolver Scan Position (-32768 to +32767)
216 / 1216
(RES_STR_POS%)
Resolver Strobe Position (-32768 to 32767)
217 / 1217
(RPM%)
Revolutions Per Minute
218 / 1218
(POS_ERR%)
Position Error (-4095 to +4095)
219 / 1219
(SPI_OUT%)
Speed Loop P+I Output (-4095 to +4095)
220 / 1220
(WR2_COMP%)
Speed Loop Feedforward Output (-4095 to +4095)
221 / 1221
(SLP_RPM%)
RPM Slip