Rockwell Automation 440R MSR23M Minotaur Safety Relay User Manual
Msr23m, Minotaur
PRESSURE SENSITIVE SAFETY MAT MODULE
MODUL FÜR DRUCKSENSITIVE-SICHERHEITSSCHALTMATTEN
MODULE POUR TAPIS SENSIBLES A LA PRESSION
MINOTAUR
MSR23M
• According to EU directive for machines 98/37/EG
• According to IEC 204-1, EN 60 204-1, DIN VDE 0113-1, EN 954-1
• Safety-mat module with manual or automatic reset
• can also be used for safety edges (4 wire non resistive type)
• Safety category 4 according to DIN EN 954-1
• Output: 2 N/O + 1N/C contacts
• Monitoring of Reset-button function
• Manual reset or automatic reset when connecting the supply
voltage, switch S1
• LED indicator for state of operation
• Indicator for status of switching element
• LED indicator for channel 1 and 2
• Removable terminal strips
• Wire connection: also 2 x 1,5 mm
2
stranded ferruled (isolated),
DIN 46 228-4 or
2 x 2,5 mm
2
stranded ferruled DIN 46 228-1/-2/-3
• Width 22,5 mm
Notes
Monitoring of Reset-button function:
Monitoring of Reset-button function is only active when S12 and S22
are switched simultaneously. If the Reset-button is closed before S12, S22
is connected to voltage (also when fault across Reset-Button), the output
contacts will not close.
A fault across the Reset-button which occurred after activation of the
relay, will be detected with the next activation and the output contacts will
not close. If a fault occurs after the voltage has been connected to
S12, S22, the unit will be activated because this fault is similar to the
normal Reset-function. The gold plated contacts of the MSR23M mean that
this module is also suitable for switching small loads of 1 mVA - 7 VA,
1 mW - 7 W in the range 0,1 - 60 V, 1 - 300 mA. The contacts also permit
the maximum switching current. However since the gold plating will be
burnt off at this current level, the device is no longer suitable for switching
small loads after this.
Approvals and marking
• Control unit for safety mats and safety edges (4 wire non resistive type)
Applications
Indicators
upper LED:
ON when supply connected
lower LEDs:
ON when relay K1 and K2 energized
ET
Circuit diagrams
S33 S34
A1
31
24
23
13
S21
S11
14
S22
32
S12
A2
K1
K2
A1
S11
S12
S34
S33
S22
A2
S21
13
31
23
14
32
24
S33 S34
31
24
23
13
S21
S11
14
S22
32
S12
K1
K2
A1
S11
S12
S34
S33
S22
A2
S21
13
31
23
14
32
24
A1
A2
Part No. 440R-P23073 - 24V DC supply
Part No. 440R-P23074 - 110V AC supply
Function diagram
Block diagram
118mm
Part No. 440R-P23073 - 24V DC supply
22.5mm
86mm
* Line fault detection
at the Reset push button
Power
Reset
Safety input
118mm
Part No. 440R-P23074 - 110V AC supply
45mm
86mm
R