Rockwell Automation 440R MSR23M Minotaur Safety Relay User Manual

Msr23m, Minotaur

background image

PRESSURE SENSITIVE SAFETY MAT MODULE
MODUL FÜR DRUCKSENSITIVE-SICHERHEITSSCHALTMATTEN
MODULE POUR TAPIS SENSIBLES A LA PRESSION

MINOTAUR

MSR23M

• According to EU directive for machines 98/37/EG
• According to IEC 204-1, EN 60 204-1, DIN VDE 0113-1, EN 954-1
• Safety-mat module with manual or automatic reset
• can also be used for safety edges (4 wire non resistive type)
• Safety category 4 according to DIN EN 954-1
• Output: 2 N/O + 1N/C contacts
• Monitoring of Reset-button function
• Manual reset or automatic reset when connecting the supply

voltage, switch S1

• LED indicator for state of operation
• Indicator for status of switching element
• LED indicator for channel 1 and 2
• Removable terminal strips
• Wire connection: also 2 x 1,5 mm

2

stranded ferruled (isolated),

DIN 46 228-4 or
2 x 2,5 mm

2

stranded ferruled DIN 46 228-1/-2/-3

• Width 22,5 mm

Notes

Monitoring of Reset-button function:
Monitoring of Reset-button function is only active when S12 and S22
are switched simultaneously. If the Reset-button is closed before S12, S22
is connected to voltage (also when fault across Reset-Button), the output
contacts will not close.
A fault across the Reset-button which occurred after activation of the
relay, will be detected with the next activation and the output contacts will
not close. If a fault occurs after the voltage has been connected to
S12, S22, the unit will be activated because this fault is similar to the
normal Reset-function. The gold plated contacts of the MSR23M mean that
this module is also suitable for switching small loads of 1 mVA - 7 VA,
1 mW - 7 W in the range 0,1 - 60 V, 1 - 300 mA. The contacts also permit
the maximum switching current. However since the gold plating will be
burnt off at this current level, the device is no longer suitable for switching
small loads after this.

Approvals and marking

• Control unit for safety mats and safety edges (4 wire non resistive type)

Applications

Indicators

upper LED:

ON when supply connected

lower LEDs:

ON when relay K1 and K2 energized

ET

Circuit diagrams

S33 S34

A1

31

24

23

13

S21

S11

14

S22

32

S12

A2

K1

K2

A1

S11

S12

S34

S33

S22

A2

S21

13

31

23

14

32

24

S33 S34

31

24

23

13

S21

S11

14

S22

32

S12

K1

K2

A1

S11

S12

S34

S33

S22

A2

S21

13

31

23

14

32

24

A1

A2

Part No. 440R-P23073 - 24V DC supply

Part No. 440R-P23074 - 110V AC supply

Function diagram

Block diagram

118mm

Part No. 440R-P23073 - 24V DC supply

22.5mm

86mm

* Line fault detection
at the Reset push button

Power

Reset

Safety input

118mm

Part No. 440R-P23074 - 110V AC supply

45mm

86mm