Rockwell Automation 44887-PUB, 44887 Enwatch User Manual
Page 26
Publication GMSI10-UM031C-EN-E - January 2009
22 Installing the Enwatch
Sampling rate
64 to 51200 Hz by 1
Number of synchronous time averages
1, 2, 4, 8, 32 ... 32768
Sample length
Multiple of 256 bytes, maximum sample 32768 bytes if no trigger, 16384 bytes with
pre-trigger (not used in first version of Enwatch)
Filter settling time
HP 0.36 Hz 18 seconds
HP 2.67 Hz 3 seconds
HP 5.3 Hz 1.2 seconds
HP 23.8 Hz 0.3 seconds
Integrator HP 0.36 Hz 25 seconds
Integrator HP 2.67 Hz 8 seconds
Integrator HP 5.3 Hz 1.5 seconds
Integrator HP 23.8 Hz 0.8 seconds
gSE 200 Hz 88 milliseconds
gSE 5 kHz 2 milliseconds
Core 0.7 seconds
Time constant of 0.03 seconds 300 milliseconds
Time constant of 0.006 seconds 60 milliseconds
Time constant of 0.0012 seconds 12 milliseconds
Time constant of 0.00024 seconds 3 milliseconds
Trigger delay
0-32768 samples. Emonitor always uses 0.
Trigger channel
1-4 channels, TTL input 5-20 V
Maximum combined trigger current (channels 1-4), not to exceed 100mA.
Gain control
X1, X10, X100, X1000, X5, X50, X500, X5000
Download X1 always. The Enwatch unit autoranges and returns back the current gain for
rescaling.
Anti-Alias filter
20 kHz, 2 kHz, 500 Hz, 100 Hz. This is read only. The Enwatch unit selects the proper filter.
Table 1.16 Enwatch measurement capabilities
Product Feature
Capability
FMAX
Sampling Rate
FMAX
Sampling Rate
25
64
2000
5120
50
128
3200
8192
100
256
4000
10240
200
512
5000
12800
400
1024
6400
16384
500
1280
8000
20480
800
2048
10000
25600
1000
2560
16000
40960
1600
4096
20000
51200