48

Rockwell Automation Publication IASIMP-QS028A-EN-P - July 2012

Chapter 3 Use a PowerFlex 40 Drive in an RSLogix 5000 Project

Test the PowerFlex 40 Tags

1.

Move the controller’s mode switch
to the RUN position.

2.

In the configuration tree, double-
click Controller Tags.

3.

Change the tag
O.CommandRegister.Run
tag to 1.

The 1769-SDN scanner module
transitions to Run mode.

4.

Expand the PowerFlex 40
output tag.

In this case the tag is named Local_SDN_scanner_module_N02_POL_O.

5.

Change the O.Reference tag to a value of 10.

The value 10 equals 1.0 Hz. This is the speed to which your drive accelerates.

RUN

REM

PROG

PowerFlex 40 tags are identified in the description column.