beautypg.com

C.3 spare parts kits – Rockwell Automation SD3100 DISTRIB PWR SYS SD3100 DC PWR MODULE User Manual

Page 72

background image

C-2

SD3100 Power Modules

C.3 Spare Parts Kits

Type of Kit

Current

Code

1

1. R = 1250A, S = 1650A, T = 3000A.

460 VAC

575 VAC

660 VAC

Brief Description

Line RC Suppressor
(Option 14LSP)

R,S,T

2300-SPB01A

2300-SPB01A

2300-SPB02A

1 PCB with 2 sets of fuses

Air Flow Switch PCB
(Option 14AFL)

R,S

2300-SPP01A

2300-SPP01A

2300-SPP01A

1 PCB with 0.5A power supply

T

2300-SPP02A

2300-SPP02A

2300-SPP02A

1 PCB with 1.1A power supply

Air Flow Switch
(Option 14AFL)

R,S

2300-SPK03A

2300-SPK03A

2300-SPK03A

T

2300-SPK01A

2300-SPK01A

2300-SPK01A

Line MOVs

R,S,T

2300-SPJ02A

2300-SPJ03A

2300-SPJ04A

1 set

Armature SCRs

R

2361-SPG01A

2361-SPG01A

2361-SPG01A

2 SCRs

S

2361-SPG02A

2361-SPG02A

2361-SPG02A

2 SCRs

T

2361-SPG03A

2361-SPG03A

2361-SPG03A

2 SCRs

Positive (Top)
Regenerative Armature
Assemblies

R

SD3100-SPA01A

SD3100-SPA01A

SD3100-SPA01A

S

SD3100-SPA05A

SD3100-SPA05A

SD3100-SPA05A

T

2361-SPA05A

2361-SPA05A

2361-SPA05A

Negative (Bottom)
Regenerative Armature
Assemblies

R

SD3100-SPA02A

SD3100-SPA02A

SD3100-SPA02A

S

SD3100-SPA06A

SD3100-SPA06A

SD3100-SPA06A

T

2361-SPA06A

2361-SPA06A

2361-SPA06A

Positive (Top) Non-
Regenerative Armature
Assemblies

R

SD3100-SPA03A

SD3100-SPA03A

SD3100-SPA03A

S

SD3100-SPA07A

SD3100-SPA07A

SD3100-SPA07A

Negative (Bottom) Non-
Regenerative Armature
Assemblies

R

SD3100-SPA04A

SD3100-SPA04A

SD3100-SPA04A

S

SD3100-SPA08A

SD3100-SPA08A

SD3100-SPA08A

Bridge Fan

R,S

2361-SPH01A

2361-SPH01A

2361-SPH01A

T

2361-SPH02A

2361-SPH02A

2361-SPH02A

Bridge Fan Door Filter

T

2361-SPK02A

2361-SPK02A

2361-SPK02A

Fiberglass 20” x 30” x 1”, 1
required, 6 per kit.

Slide-In Fan

T

2361-SPH03A

2361-SPH03A

2361-SPH03A

Loose Power Fuses

R

2361-SPE08A

2361-SPE08A

2361-SPE08A

2 fuses per kit

2

2. Drive requires 12 fuses.

S

2361-SPE09A

2361-SPE09A

2361-SPE09A

2 fuses per kit

2

T

2361-SPE10A

2361-SPE10A

2361-SPE10A

3 fuses per kit

3

3. Drive requires 18 fuses.

Power Fuse Assembly

T

2361-SPE11A

2361-SPE11A

2361-SPE11A

1 assembly containing 3 fuses in
parallel

Input Line Fuses

R

2361-SPE12A

2361-SPE12A

2361-SPE12A

S

2361-SPE13A

2361-SPE13A

2361-SPE13A

T

2361-SPE14A

2361-SPE14A

2361-SPE14A

Snubber Assembly

R

2361-SPB03A

2361-SPB03A

2361-SPB03A

S

2361-SPB01A

2361-SPB01A

2361-SPB01A

T

2361-SPB02A

2361-SPB02A

2361-SPB02A