beautypg.com

Rockwell Automation 2711P-RSACDIN AC Power Supply User Manual

Page 10

background image

10 AC Power Supply for PanelView Plus/PanelView Plus CE Terminals

Publication 2711P-IN005C-EN-P - March 2007

Output Current

3 A maximum horizontal mount

Minimum Load

50 mA

Overvoltage Protection

Output internally limited to 35V dc. Cycle power to reenergize.

Overcurrent Protection

Current limit 3.2 A minimum (107% minimum)

Leakage Current

0.5 mA rms maximum @ rated input and output

Isolation Voltage

2830V dc for 1 second

General Specifications

Mounting

Horizontal on a DIN rail.
Wall or panel mount with 1794-NM1 panel mounting kit

Terminal Screw Torque

5-7 lb-in (0.5…0.6 Nm)

Dimensions, HxWxD

3.4 x 2.7 x 2.7 in.
87 x 68 x 69 mm

Environmental Specifications

Operating Temperature

IEC 60068-2-1 (Test Ad, Operating Cold)
IEC 60068-2-2 (Test Bd, Operating Dry Heat)
IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
32…131 °F (0…55°C)

Storage Temperature

IEC 60068-2-1 (Test Ab, Unpackaged, Nonoperating Cold)
IEC 60068-2-2 (Test Bb, Unpackaged, Nonoperating Dry Heat)
IEC 60068-2-14 (Test Na, Unpackaged, Nonoperating Thermal Shock)
-40…185°F (-40…85 °C)

Relative Humidity

IEC 60068-2-30 (Test Db, Unpackaged, Nonoperating Damp Heat)
5…95%, noncondensing

Shock

Operating

Non Operating

IEC 60068-2-27 (Test Ea, Unpackaged Shock)
30g
50g

Vibration

IEC 60068-2-6 (Test Fc, Operating)
5g @ 10…500 Hz

ESD Immunity

IEC 61000-4-2
4 kV contact discharges
8 kV air discharges

Radiated RF Immunity

IEC 61000-4-3
10V/m with 1 kHz sine-wave 80% AM from 30…1000 MHz

EFT/B Immunity

IEC 61000-4-4
±2 kV @ 5 kHz on power ports

Surge Transient Immunity

IEC 61000-4-5
±1 kV line-line (DM) and ±2 kV line-earth (CM) on ac power ports