Environment and Enclosure Information

Review the information on enclosures and environments before installing the
product.

ATTENTION

Environment and Enclosure

This equipment is intended for use in a Pollution Degree 2 industrial
environment, in overvoltage Category II applications (as defined in IEC
publication 60664-1), at altitudes up to 2000 m (6561 ft) without derating.

This equipment is considered Group 1, Class A industrial equipment according
to IEC/CISPR Publication 11. Without appropriate precautions, there may be
potential difficulties ensuring electromagnetic compatibility in other
environments due to conducted as well as radiated disturbance.

This equipment is supplied as open type equipment. UL recognized equipment
must be mounted within an enclosure that is suitably designed for those
specific environmental conditions that will be present and appropriately
designed to prevent personal injury resulting from accessibility to live parts.
The interior of the enclosure must be accessible only by the use of a tool. UL
listed equipment need not be mounted inside another enclosure. Subsequent
sections of this publication may contain additional information regarding
specific enclosure type ratings that are required to comply with certain product
safety certifications.

In addition to this publication, see:

• Industrial Automation Wiring and Grounding Guidelines, for additional

installation requirements, Allen-Bradley publication 1770-4.1.

• NEMA Standards publication 250 and IEC publication 60529, as applicable,

for explanations of the degrees of protection provided by different types of
enclosure.