beautypg.com

Replacing the battery – Rockwell Automation 6182 Industrial Computer Installation Instructions User Manual

Page 16

background image

16

RAC6182 Industrial Computer

Publication 6182-IN001D-MU-P

Important:

Performance degradation of your Ethernet communications is
likely to result if the unit or cables are subjected to extreme
radiated or conducted high-frequency noise. It is the user’s
responsibility to properly route cable and condition input power
in order to improve communication reliability.
Proper cable routing and power conditioning is required to ensure
reliable Ethernet communications in industrial environments.
Rockwell Automation recommends that all Ethernet cabling be
routed through dedicated metal conduits. Installing ferrite bead
filters at cable ends may also improve reliability.

Replacing the Battery

The RAC6182 Computer contains a battery to maintain the CMOS SRAM and
real-time clock. The battery is located in a battery holder on the RAC6182
Computer backplane. Replace this battery as needed with a Panasonic battery,
part number CR2032.

ATTENTION: There is a danger of explosion if the battery is
incorrectly replaced. Replace only with the same or equivalent
type recommended by the manufacturer. Dispose of used
batteries according to the manufacturer's instructions.