Rockwell Automation 6157-C User Manual User Manual
Page 49
Industrial 19" CRT Monitor
49
Publication 6157-UM001A-EN-P
Environmental
Panel Rating
Panel Mount
Rack Mount
NEMA 4/4X/12, (IP65/IP52) (6157-CE/6157-CF)
NEMA 1 (IP10) (6157-CB)
Operating Temperature
0ºC to 40ºC
Storage Temperature
-20ºC to 60ºC
Relative Humidity
10% to 90% non-condensing
Operating Altitude
Sea level to 10,000 ft (3,048m)
Non-Operating Altitude
Sea level to 40,000 ft (12,192m)
Operating Electrostatic
Discharge
8.0K VDC (IEC 801-2, level 3)
Non-Operating Electrostatic
Discharge
20.0K VDC
Operating Shock
10g (1/2 sine, 11msec)
Non-Operating Shock
20g (1/2 sine, 11msec)
Operating Vibration
0.003in. p-p, 5-57Hz,
0.5g peak, 57-640Hz sine
Non-Operating Vibration
0.006in. p-p, 5-57Hz,
1.0g peak 51-640Hz sine
Electrical
Line Voltage
100-130/198-264 VAC, autoswitching
Line Frequency
50-60Hz
Ground Leakage
1.0 uA max at 1.5K VDC
Power Consumption
135W max
Physical
Panel Mount
Panel Bezel Dimensions
(W x H x D)
19.0 in. x 15.7 in. x 0.43 in. (483mm x 399mm x
11mm)
Overall Dimensions (from
rear surface of front panel
to back)
16.75 in. x 14.0 in. x 18.1 in. (426mm x 356mm x
460mm)
Net Weight
64lb (29.0kg)
Rack Mount
Panel Bezel Dimensions
(W x H x D)
19.0 in. x 15.7 in. x 0.4 in. (482mm x 399mm x 10mm)
Overall Dimensions (from
rear surface of front panel to
back)
16.75 in. x 14.0 in. x 18.2 in. (426mm x 356mm x
462mm)
Net Weight
64lb (29.0kg)
Certifications - Agency Approvals
UL 1950 Recognized Component,
C-UL 950 Recognized Component
LVD (73/23/EEC)
EN 60950 (per UL 1950 3rd ed. without D3 dev.)
EMC (89/336/EEC)
Emissions
Immunity
EN 50081-2
EN 50082-2
Australian C-Tick
DHHS
DHHS 21 CFR 1020.10 Compliant
FCC Class A