Running the application – Rockwell Automation 2707-NP DTAM PLUS GETTING STARTED USER MANUAL User Manual
Page 73
Chapter 8
Running the Application
8–3
You are now ready to run the sample application.
1. Cycle power to the DTAM Plus to activate the new DIP switch settings.
2. The DTAM Plus displays a series of diagnostic tests, enters run mode,
loads the application and then displays the Main Menu of the application.
2 Tank 1 Parameters
3 Batch Recipes
4 Alarm Demo
1 Pump Application
3. Press the [1] key on the DTAM Plus.
A Bar Graph display appears showing the RPM of the pump. The Bar
Graph and data display should change as the data in the SLC register
T4:11.2 changes.
1276 RPM
East Main Pump Speed
0
2000
4. Press the [NEXT] or [PREV] key to display the Main Menu.
5. Press [2] to access the Sub-Menu.
2
3
1 Tank Temp Desired
Mixer Status
Tank Level
6. Press [1] to enter a new tank temperature.
Actual:150 Deg. C.
Desired:_
Enter Desired Temp
Valid Range:140–170
7. Enter a value of 200 and press the [
] key.
An Input Error appears because the value is out of the 140–170 range.
LOW LIM
140
** Input Error **
170
Presss ”Y” to Reenter
HIGH LIM
8. Press Y. You are prompted to enter a new temperature.
9. Enter 150 and press [
]. You return to the Main Menu.
2 Tank 1 Parameters
3 Batch Recipes
4 Alarm Demo
1 Pump Application
10. Press the [2] key to access the Sub-Menu.
11. Press [2] again to display the tank level parameters.
33 Gallons
Press Next
Tank Level
10% Full
Running the Application