background image

4 Mounting Clips

Publication 2711P-IN006B-MU-P - March 2007

Install the Mounting Clips

Follow these steps to install the mounting clips.

1. Install the mounting clips on the terminal.

The ends of the clips slide into the slots on the terminal. Tighten the
mounting clip screws by hand until the gasket seal contacts the mounting
surface uniformly.

2. Alternately tighten the mounting clip screws to a torque of:

• 1.13 Nm (10 lb-in) for the RAC6182 device.
• 0.90…1.1 Nm (8…10 lb-in) for the 2711P PanelView Plus or PanelView

Plus CE device.

Do not overtighten.

ATTENTION

Tighten the mounting clips to the recommended torque to provide a proper seal
and to prevent damage to the device. Allen-Bradley assumes no responsibility
for water or chemical damage to the product or other equipment within the
enclosure because of improper installation.

4 Clips

1

4

3

2

6 Clips

2

4

6

5

1

3

8 Clips

1

2

3

4

5

6

7

8

The recommended torque sequences

are shown below.