Rockwell Automation 9000 Series 9000 Intrinsically Safe Photoelectric Sensors User Manual
Dim ens ions —m m (inc h es ), Ty p ical r esp on se c u rv e, Cable version
![background image](/manuals/580147/1/background.png)
1
installation
Instr
u
ctions
—Ser
ies
9000
P
HOT
O
SWITCH
R
In
trin
sically
S
af
e
P
h
o
to
electric
S
en
so
rs
Sensors
Tra
nsm
itte
d
Bea
m
So
urce
Re
cei
ve
r
1
Catalog
Nu
m
ber
2m
Cab
le
42GRL
--9
540
42GRR
--9
500
4-
pin
DC
M
icro
Q
D
42GRL
--9
540
--Q
D
42GRR
--9
500
--QD
4-
pin
DC
M
ini
Q
D
42GRL
--9
540
--QD1
42GRR
--95
00
--QD1
2
Se
nsing
Distance
10
6m
(3
50ft)
3
Fi
el
d
of
Vie
w
1.
5
_
4
Se
nsitivity
Ad
jus
tm
ent
Ye
s
5
Tra
nsmitting
LE
D
Inf
rare
d
880m
n
—
6
Indicato
rs
Ye
llow
:P
ow
er
Ye
llow:
Po
wer
,G
reen:
Outpu
t,and
Red
:Mar
gin
7
Su
pply
Vo
ltage
14
--30V
DC
13
--3
0V
DC
8
Max
Cur
ren
tConsump
tion
16
m
A
25m
A
9
Outpu
t
—
NP
N
and
PN
P
10
Max
Load
Cur
rent
—
15mA
(NP
N)
8.
5mA
(P
NP
)
11
Max
Leakage
Curre
nt
—
10
A
12
Response
Time
10ms
(ON)
5m
s
(OFF
)
13
Vo
lta
ge
Dro
p
4.5V
(NP
N)
6.0
V
(P
NP
)@
M
ax
Loa
d
Curr
ent
14
Oper
ating
Tem
per
ature
--3
4
_
Ct
o+
70
_
C(
--2
9
_
F
to
+158
_
F)
15
Relative
Hum
idity
5%
to
95%
16
Housing/L
ens
Ma
terial
Ac
rylic
17
En
vironm
ental
Prote
ction
NE
MA
3,
4,
4X
,6
P,
13
,IP
67
(IE
C
529);
1200psi
(8270
kP
a)
W
ashdown
18
Vibr
ation
10
--55
Hz,
1mm
am
plitude,
Meets
or
exce
eds
IE
C
6094
7--5
--2
19
Sh
oc
k
30
G
with
1ms
pulse
du
ration,
Meets
or
exce
eds
IE
C
6094
7--5
--2
20
Ele
ctrical
Protect
ion
Fa
lse
Pulse,
Reve
rse
Po
larity
,O
ve
rload,
Sh
ort
Circuit
21
Ap
prova
ls
(Ordin
ary
Lo
cations)
UL
Liste
d,
CS
A
Cer
tified,
CE
Mar
ked
fo
ra
llapp
lica
ble
dire
ctives
22
Ap
prova
ls
(Hazard
ous
Lo
cation)
Ag
ency
Standar
d
FM
3610
,361
1
Intr
insicall
y
Safe
for
Class
I;D
ivision
1;
G
roup
s
A,
B,
C,
and
D
Hazar
dous
(C
lassified)
Lo
cations.
Vm
ax=3
1.5V
,Imax=1
50mA
,P
m
ax=
0.95W
,C
i=0u
F,
Li=0m
H,
T4,
Ty
pe
4X
3810
,3600
Nonincen
dive
for
Cla
ss
I;
Division
2;
Gr
oups
A,
B,
C,
D;
T4
,T
yp
e
4X
CS
A
CS
A--
C22.
2
No.
15
7
CS
A--
C22.
2
No.
21
3
CS
A--
C22.
2
No.
14
2
Ex
ia
Intr
insi
ca
lly
Safe
for
Class
I;D
ivi
sion
1;
G
roups
A,
B,
C,
an
d
D;
Class
III,
Division
1,
Vm
ax=3
1.5V
,Imax=1
50mA
,Ci=0
F
and
Li=0mH,
T3A
,T
ype
4X
.
Nonincen
dive
for
Cla
ss
I;
Division
2;
Gr
oups
A,
B,
C,
D;
T3
A,
Ty
pe
4X
Ty
p
ical
R
esp
on
se
C
u
rv
e
10000
1
4
10
40
100
400
1000
4000
Op
er
atin
g
Dist
ance
Operating Margin
41.
91
(1.6
50)
5.46
(0
.215)
32
.66
(1.28
6)
74.9
3
(2.9
50)
Re
f
55.62
(2.190)
16
.76
(0.66
0)
M30
X
1.5
Ex
terna
lThre
ad
1/
2
NPS
M
Intern
al
Thr
ead
24.6
9
(0.97
0)
30
.35
(1
.195)
15
.87
(0
.625)
42
.41
(1
.670)
20.9
6
(0.82
5)
7.6
2
(0.
300)
15
.24
(0.600)
5.21
(0.205
)X
8.13
(0.320)
Sl
ot,
2
PL
CS
Cable
Version
Cable
Length
2m
(6.5
)
6.5
(0.255/
0.245)
Dia.
Dim
ens
ions
—m
m
(inc
h
es
)
103.63
(4.080
)
M
ax.
Travel
40
.00
(1.5
75)
Moun
ting
Hole
Center
lin
e
13.9
7
(0.5
50)
17.78
(0.7
00)
Micro
Style
Mini
Style
C
o
nn
ecto
r
V
er
sio
n
102
(4)
34
In
trin
sic
Sa
fety
Ba
rri
er
16
0m
A
16
0m
A
16
0m
A
16
0m
A
12
12.5
(0.5)
10
2
(4)
56
(2.1
875)
70
(2
.75)
93.5
(3
.75
)
A
llen-Brad
le
y
S
erie
s
897
H
Zener
Diode
Barr
ier
#6
4--
13
6
0.3
m
(1ft)
D
IN
R
ai
lM
ou
nti
ng
K
it
0.3
m
(1
)
1.
8m
(5
)
3m
(10
)
15m
(5
0
)
30m
(1
00
)
150
m
(500
)
1