The following table can help you identify the potential cause of
problems you may encounter while using the 6156 Industrial
Monitor.
!
ATTENTION: When attempting to correct a problem,
do not change any adjustments located on the monitor
chassis’ left side (as viewed from the front of the
monitor). These adjustments are for factory trained
personnel using special test and alignment equipment.
Symptom
Possible Cause
Procedure
No Video
No power
Check to see if rear panel LED is illuminated; if not, check power wiring;
check for presence of proper voltage; check AC line fuse
Video cable problem
Check for proper video cable installation; replace suspected faulty cable
Brightness/Contrast controls
misadjusted
Adjust brightness/contrast controls
Images distorted or off-center
or
Video adapter not compatible
or misconfigured
Check to insure that the graphics adapter is a VGA type and is configured to
provide a display compatible with the monitor
or
Video not synced (screen rolls)
Monitor misadjusted
Adjust width, horizontal position, and vertical position controls
y
(
)
Video cable problem
Check for proper video cable installation; replace suspected faulty cable
Sync select switch set
improperly (BNC Version only)
Set sync select switch to correct source
Color appears wrong
Video cable problem
Check for proper video cable installation; replace suspected faulty cable
Color appears wrong
Build-up of residual
magnetism
Manually degauss unit
No keypad communications
Keypad cable problem
Check for proper cable installation; replace suspected faulty cable
No touchscreen
communications
Touchscreen cable problem
Check for proper cable installation; replace suspected faulty cable
Other touchscreen failures
Various
Refer to additional documentation provided with unit from touchscreen
manufacture