beautypg.com

Rockwell Automation 1768-ENBT CompactLogix EtherNet/IP Communication Module Installation Instructions User Manual

Page 23

background image

CompactLogix EtherNet/IP Communication Module 23

Rockwell Automation Publication 1768-IN002B-EN-P - August 2010

Environmental Specifications - 1768-ENBT

Attribute

1756-ENBT

Temperature, operating
IEC 60068-2-1 (Test Ad, Operating Cold)
IEC 60068-2-2 (Test Bd, Operating Dry

Heat)

IEC 60068-2-14 (Test Nb, Operating

Thermal Shock)

0…60

°C (32...140 °F)

Temperature, nonoperating
IEC 60068-2-1 (Test Ab, Unpackaged

Nonoperating Cold)

IEC 60068-2-2 (Test Bb, Unpackaged

Nonoperating Dry Heat)

IEC 60068-2-14 (Test Na, Unpackaged

Nonoperating Thermal Shock)

-40…85

°C (-40...185 °F)

Relative humidity
IEC 60068-2-30 (Test Db, Unpackaged

Damp Heat)

5…95% noncondensing

Vibration
IEC 60068-2-6 (Test Fc, Operating)

5 g @ 10…500 Hz

Operating shock
IEC 60068-2-27 (Test Ea, Unpackaged

Shock)

30 g

Nonoperating shock
IEC 60068-2-27 (Test Ea, Unpackaged

Shock)

50 g

Emissions
CISPR 11

Group 1, Class A

ESD immunity
IEC 61000-4-2

4 kV contact discharges
8 kV air discharges

Radiated RF immunity
IEC 61000-4-3

10V/m with 1 kHz sine-wave 80%AM from
30…2000 MHz
10V/m with 200 Hz 50% Pulse 100%AM at
900 MHz
10V/m with 200 Hz 50% Pulse 100%AM at
1890 MHz
1V/m with 1 kHz sine-wave 80%AM from
2000…2700 MHz

EFT/B immunity
IEC 61000-4-4

±2 kV at 5 kHz on communication ports