Rockwell Automation 20G PowerFlex 750-Series EMC Plate and Cores - Frames 1…7 User Manual
Page 4

4
Rockwell Automation Publication 750-IN006G-MU-P - February 2014
PowerFlex 750-Series EMC Plate and Core(s) – Frames 1…7
1
2…3
4…5
Step
Frame Procedure
6
Input Power (R, S, T)
Shielded or Unshielded
to PE Stud
to PE Stud
Motor Cable (U, V, W)
Shielded
1 Loop
(each wire)
T20 or F - 6.4 mm (0.25 in.)
1.8 N•m (16 lb•in)
PE
I/O Shields
IP20,
NEMA/UL Type 0
Flange Mount
Input Power (R, S, T)
Shielded or Unshielded
Motor Cable (U, V, W)
Shielded
to PE Stud
to PE Stud
I/O Signal Shields
I/O Signal Wires
M4 (7 mm) 1.8 N•m (16 lb•in)
PE
Frame 2 Shown
IP20,
NEMA/UL Type 0
Flange Mount
to PE Stud
to PE Stud
Input Power (R, S, T)
Shielded or Unshielded
Motor Cable (U, V, W)
Shielded
M6 (10 mm) 5.6 N•m (50 lb•in)
PE
I/O Signal Shields
I/O Signal Wires
The motor cable ground wire connects to the motor PE stud in the drive, however it should
DRIVES-IN001
for further information.
Frame 5 Shown