Waldmann PULSE HFMD version VFC IV - without MFT User Manual
Page 11

11
Operating Manual Light Control „PULSE HFMD - Vers. IV without MFT“
ENG
Activate setting level 1
Press both keys
for at least 10 seconds
Actuation
Display
LED II flashes white
Change the basic settings - Change the setting level
Do not actuate any key for at
least 10 seconds
Activate setting level 2
Press both keys again
for 5 seconds *
LED II flashes red
Activate setting level 3
Press both keys again
for 5 seconds *
LED II flashes green
Leave parameterisation mode
LED I or LED II lit red
* Within 10 seconds a change from one level to the next one is possible.
Activate setting level 4
Press both keys again
for 5 seconds *
LED II flashes blue
LED II
LED II
LED II
LED II
Fig. 4
Key I
+ LED I
Sensor
Key II
+ LED II