Sockets 9, Sockets description – Vicor VI Chip Remote Sense PRM Evaluation Board User Manual
Page 9
![background image](/manuals/574924/9/background.png)
UG:016
vicorpower.com
Applications Engineering: 800 927.9474
Page 9
Sockets Description
Each socket accepts 0.015 – 0.025 inch diameter leads for easy installation of solid wires
and through-hole components for use with external circuit and test equipment.
Table 4.
Sockets description
Reference
Functional
Functional
Designator
Name
Description
H57,
Input
H58 Capacitor
Sockets are used for easy installation of through-hole 100 V rated
(C
IN
)
aluminum-electrolytic capacitor.
H32,
Output
Sockets are used for easy installation of through-hole 100 V rated
H33
Capacitor
aluminum-electrolytic capacitor.
(C
OUT
)
Ensure proper polarity with short leads while installing.
H49,
H53
Not Applied.
H50,
H54
Not Applied.
H41,
Compensation Used for easy installation of through-hole compensation capacitor C20
H43
Capacitor
in feedback path of error amplifier. Default through-hole 4700 pf capacitor
(C20)
is added in the box. Used only with Remote Sense Operation.
H42,
Compensation Used for easy installation of the through-hole compensation resistor R28 in feedback
H44
Resistor
path of the error amplifier. Default through-hole 20 K resistor is added in the box.
(R28)
Used only with Remote Sense Operation.
H39,
Integrator
H40
Capacitor
Used for easy installation of through-hole compensation capacitor C19.
(C19)
Differential
H47,
Input
Used for easy installation of through-hole resistor R33 for non-isolated
H48
Resistor
differential sensing in Remote Sense Operation.
(R33)
Differential
H51,
Input
Used for easy installation of through-hole resistor R41 for non-isolated
H52
Resistor
differential sensing in Remote Sense Operation.
(R41)
H55,
Soft-start
Used for easy installation of the through-hole capacitor on top of default 0.1uF
H56
Capacitor
to soft-start the PRM output voltage in Remote Sense Operation.
(C24)
H46,
Used to insert wires to hook up the network analyzer measuring probes
H45
to measure stability in Remote Sense Operation.
H30,
CS+
Used to insert test leads to measure the voltage across R25.
H31
CS-