Remote Sense operating mode using PRM

®

and VTM

®

:

Non-Isolated Remote Sensing (Differential Sensing)

Mode select switch S10 setting: keep the switch S10 setting at all positions as shown in
the following illustration.

Note: To use this configuration, the VTM isolation must be broken by tying VTM -IN and VTM -OUT
together.

The following table describes the switch configuration.

REMOTE SENSE (Differential)

ON

OFF

1

2

3

4

5

6

7

8

9

10

Postion

number

Switch

Position

ON or OFF

Connection

Number

1

OFF

TM pin must be left open. This switch position cannot be put in the ON position.

2

ON

PR pin is connected to output of external error amplifier.

3 ON

IF pin is connected to output of external current sense amplifier to set the

constant current limit.

4 ON

RE pin is connected to input of the external voltage reference circuit to

generate voltage reference for external error amplifier.

5

ON

VS pin is connected to power VCC of the op-amp and current sense IC.

6

OFF

NC pin must be left open. This switch position cannot be put in the ON position.

7 OFF

PRM +OUT pin is NOT connected to local sense (single ended) of the remote

sense control circuitry.

8

Don’t care

9 ON

VTM +OUT (+SENSE) pin is connected to positive input (+SENSE_B) of the

differential buffer of remote sense control circuitry.

10 ON

VTM –OUT (-SENSE) pin is connected to negative input (-SENSE_B) of the

differential buffer of remote sense control circuitry.

Table 8.

Switch configuration in

differential sensing

1206

1K

R36

SG

SG

VCC

R32

1206

C22

1206

C19

1206

EAO

R33

1206

SG

R41

1206

+SENSE_B

-SENSE_B

LOCAL SENSE_+

2

3

1

4

8

SO8

U11A

6

5

7

U11B

1206

R29

1206

20K

R28

1206

4.7nF

C20

C21

0603

H 39

H 40

H 43

H 44

H 42

H 41

IMON

R27

1206

H 48

H 47

H 51

H 52

1206

R30

H 46

H 45

TP38

TP37

OPEN

OPEN

OPEN

1206

1.27K

R31

1206

1.27K

R42

VREF

To VTM ouput (+S/–S)

through S10 and J10

To PR through S10

Preinstalled component

and connections

User installed

component

Figure 14.

Remote Sense: non-isolated

remote sensing (differential)

control circuitry

BLUE highlight =

Pre-installed component

GREEN highlight =

user installed component

Figure 13.

Remote Sense

(differential)