Do not apply the finish coat until after the fill coat has developed sufficient suction. In good drying weather this
takes about two hours after the fill coat has set; in damp and/or cold weather the time interval might extend
overnight. Thus proper heat and ventilation should be provided. Apply a finish coat of job-sanded D
IAMOND
Brand
Interior Finish Plaster to provide a total thickness of 3/8
Љ.
Apply job-sanded D
IAMOND
Brand Interior Finish Plaster (no less than 1/4 to 1 parts by weight sand per bag of prod-
uct) to a finish thickness between 1/16
Љ minimum and 3/32Љ maximum. Scratch in a tight thin coat over the entire
area, immediately doubling back to the full thickness. Fill all voids and imperfections. Scratch and double back with
the same mix of D
IAMOND
Brand Interior Finish Plaster. When the surface has become firm, hold the trowel flat and
final trowel using water sparingly. Do not over-trowel. Best results are obtained by continuous application over the
entire ceiling. Always work to a wet edge to avoid dry joinings.
Cleanup
Clean mixing containers and tools with water immediately after use. Tightly close partially used containers. When
machines are shut down, they should be hosed off and thoroughly cleaned—made ready for a fresh start. Remove
all scaffolding, empty containers and excess materials from the job site. Sweep the floors and be sure to leave the
building and site in good condition for decoration and finishing.
Trademarks
The following trademarks used
herein are owned by United
States Gypsum or a related
company: D
IAMOND
, D
URABOND
,
E
ASY
S
AND
, F
IBEROCK
, I
MPERIAL
,
S
HEETROCK
and USG.
Note
Products described here
may not be available in all geo-
graphic markets. Consult your
U.S. Gypsum Company sales
office or representative for
information.
Notice
We shall not be liable for inci-
dental or consequential dam-
ages, directly or indirectly sus-
tained, nor for any loss caused
by application of these goods
not in accordance with current
printed instructions or for other
than their intended use. Our lia-
bility is expressly limited to
replacement of defective goods.
Any claim shall be deemed
waived unless made in writing
to us within thirty (30) days from
the date it was or reasonably
should have been discovered.
Manufactured by
United States Gypsum Company
125 South Franklin Street
Chicago, IL 60606
800 USG.4YOU (874-4968)
www.usg.com
P838/2-04
©2004, United States Gypsum Company
Printed in U.S.A.
Page 6 of 6