Safety label – Regency Horizon HZI540PB Large Gas Insert User Manual
Page 6
6
L540PB-2 / HZI540PB-2 Direct Vent Gas Insert
SAFETY LABEL
This is a copy of the labels that accompany each HZI540PB Gas Insert.
We have printed a copy of the contents here for your review.
NOTE: Regency units are constantly being improved. Check the
label on the unit and if there is a difference, the label on the unit is
the correct one.
For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with
battery back up in the same room where the gas appliance is installed.
NATURAL GAS FIREPLACE INSERT:
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. supply pressure
5“
WC
(1.25 kpa)
Low Setting Man. pressure
1.6"
WC
(0.41 kpa)
Max. Manifold pressure
3.5"
WC
(0.87 kpa)
Orifice size
#32
DMS
Minimum input
25,000
Btu/h
(7.33 kW)
Maximum input
38,000
Btu/h
(11.14 kW)
Min. supply pressure
11"
WC
(2.73 kpa)
Low Setting Man. pressure
6.4"
WC
(1.59 kpa)
Max. Manifold pressure
10"
WC
(2.48 kpa)
Orifice size
#51
DMS
Minimum input
30,000
Btu/h (8.79 kW)
Maximum input
38,000
Btu/h (11.14 kW)
PROPANE GAS FIREPLACE INSERT:
Factory Equipped For Altitude 0-4500ft. (0-1370m)
MODEL
-NG2
HZI540PB
HZI540PB
MODEL
-LP2
Model/Modele:
-NG2
HZI540PB
919-297a
DO NOT REMOVE THIS LABEL /
NE PAS ENLEVER CETTE ETIQUETTE
Serial No. / No de serie
428
428
Duplicate Serial number
Listed:
Certified for/Certifi e pour: CANADA and U.S.A.
VENTED GAS FIREPLACE HEATER
/
Tested to
Conforms to
Certified to:
: CAN/CGA-2.17-M91(R2009)
: ANSI Z21.88-2009
CSA 2.33-2009
FOYER AU GAZ À ÉVACUATION
é
VENTED GAS FIREPLACE HEATER -
NOT FOR USE WITH SOLID FUELS. /
NE PAS UTILISER AVEC DUCOMBUSTIBLE SOLIDE.
FOYER AU
GAZ À ÉVACUATION -
Model/Modele:
-LP2
HZI540PB
Й
Й
QUIP A L'UISINE POUR GAZ PROPANE
MODEL HZI540PB-LP2
Й
Й
QUIP A L'UISINE POUR GAZ NATURAL
MODEL HZI540PB-NG2
Pression d'allimentation minimum
Pression
la tubulure d' chappement basse
Pression
la tubulure d' chappement lev e
Dimensions de l'orifice
D bit Calorifique minimum
D bit Calorifique maximum
а
а
й
й
й
й
й
й
Pression d'allimentation minimum
Pression
la tubulure d' chappement basse
Pression
la tubulure d' chappement lev e
Dimensions de l'orifice
D bit Calorifique minimum
D bit Calorifique maximum
а
а
й
й
й
й
й
й
Mantel Clearances
FPI Fireplace Products International Ltd.,
Delta BC, CANADA
MADE IN CANADA /FABRIQUE AU CANADA
Minimum Clearances to Combustibles
from Insert
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and
Propane Installation Code, CSA B149.1.
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases unless a certified kit is used.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured
(mobile) home where not prohibited by local codes. See owner's manual for details
WARNING. This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original
parts have been replaced, and the fireplace re-approved by the authority having jurisdiction.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel
Gas Code ou CSA-B149.1 en vigueur.
AVERTISSEMENT : Ce foyer a été converti pour utilisation avec un foyer au gaz encastrable et ne peut être utiliser pour brûler du bois ou d'autres
combustibles solides à moins que toutes les pièces d'origine aient été remplacées et que le foyer ait été approuvé de nouveau par l'autorité compétente.
This vented gas fireplace heater is not for use with air filters.
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison
préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de
renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
Cet appareil n'est pas convertible pour une utilisation avec d'autres gaz, sauf si un kit certifié est utilisé.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison
préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de
renseignements.
Electrical supply / Électrique 115VAC, 2.5 A, 60Hz, Less than 10A
Fan Part # 911-071
A
C
B
E
K
D
L
G
Side wall
A
12”
(305mm)
Ceiling
B
60”
(1524mm)
12" Mantel Max.
C 24”
(610mm)
Min. Alcove Width
K
56"
(1422mm)
Max. Alcove Depth
L
36”
(914mm)
*Min. Hearth Width
D
14”
(356mm)
*Min. Hearth Length
E
44”
(1016mm)
Max. Mantle Depth
G
12"
(305mm)
* See installation manual for hearth requirements.
*If unit is raised 6" from the floor - no hearth
required.
@ 24" form fireplace opening
4001172