2) Lift the Burner slightly while pulling forward to clear the mixing tube.

3) To install - reverse Steps 2 and 1.

Care must be taken when installing the burner into the fi rebox.

Do not damage, knock or scrape the pilot assembly.

The fl ame sensor and ignition lead are fragile and can be damaged

easily.

*Satin black paint is included if touch ups are required.

Important Note:

A correctly installed burner - the burner is back far enough,

lower the front edge so that the front fl ange of the burner
(underneath) sits down into the grooves in the burner mount-
ing brackets Left and Right. There will be a small gap between
the Ceramic Burner and the fi rebox Bottom Flange. The Burner
should be situated about ¼” (6mm) inside the front edge of the
fi rebox.


INSTALLATION

REMOVAL

6mm

1) Remove left and right side panels by sliding them forward - see below.

Burner Mounting

Bracket Right

Burner Mounting

Bracket Left

Mixing Tube

Support

Gas Orfice

Pilot Assembly

Air

Shutter

Firebox