FPI P36-4 Zero Clearance Direct Vent Gas Fireplace

SAFETY LABEL

This is a copy of the label that accompanies
each P36 Zero Clearance Direct Vent Gas
Fireplace. We have printed a copy of the
contents here for your review. The safety
label is located on the front inside base of
the unit, visible when the bottom louver
is open.

NOTE: FPI units are constantly being
improved. Check the label on the unit and
if there is a difference, the label on the unit
is the correct one.

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE

294

294

DOOR SEAL: Please

check that the door is

properly sealed

Minimum Clearances to Combustibles /

Degagement Minimum De Materiaux Combustibles

Serial No./ No de serie

918-499a

The "Bay Louvers"

be

used with the Bay Glass option

MUST

MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.

Duplicate S/N

B

B

32"

Ceiling

W

all

W

all

A

0" Clearance to
combustibles from:

Mantel Clearances from Top:

Side Wall Clearance
from Side Facing

Alcove Clearances:

Minimum Vent Clearances:

Top, sides, bottom and rear of unit

(A) Min. 7" (177mm)

B) 6" with Flush or Bay Front
B) 8" with Barcelona Trim

Alcove approved for
Bay & Flush Louvers.

Max. Depth 36" (914mm)
Min. Width 48" (1219mm),
Min. Height 72" (1229mm)

Vertical Vent

1-1/4" (32mm)

Horizontal Top

2" (51mm)

Horizontal Side

1-1/2" (38mm)

Horizontal Bottom 1-1/2" (38mm)

(See Instruction Manual for

detailed instructions)

Й

Й

QUIP A L'UISINE POUR GAZ PROPANE

PROPANE GAS: Model P36-LP4

12"

WC/C.E. (3.00 kPa)

11"

WC/C.E. (2.74 kPa)

2.9"

WC/C.E. (0.72 kPa)

Minimum supply pressure
Manifold pressure High
Manifold pressure Low

Pression d'allimentation minimum
Pression

la tubulure d' chappement lev e

Pression

la tubulure d' chappement basse

а

й

й

й

а

й

30,000 Btu for altitude 0 - 2000 ft.
Maximum Input
Minimum Input
Orifice size
Altitude

30,000 Btu/h

(8.79 Kw/h)

15,000 Btu/h

(4.40 Kw/h)

#52

DMS

(1.61mm)

0-2000 ft/pi

(0-610m)

D bit Calorifique maximum
D bit Calorifique minimum
Dimensions de l'orifice
L'altitude

й
й

Convertible to 25,000 Btu for altitude 2000 - 4500 ft. with Orifice part #: 904-345
Maximum Input
Minimum Input
Orifice size
Altitude

25,000 Btu/h

(7.33 Kw/h)

12,600 Btu/h

(3.69 Kw/h)

#53

DMS

(1.51mm)

2000-4500 ft/pi

(610-1372m)

D bit Calorifique maximum
D bit Calorifique minimum
Dimensions de l'orifice
L'altitude

й
й

Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude

NATURAL GAS: Model P36-NG4

APPAREIL FONCTIONNANT AU NATURAL GAS
CONCU POUR ETRE POELE: Mod le P36-NG4
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
Pression à la tubulure d' chappement basse
Grandeur de l'injecteur
D bit

minimum selon

D bit

maximum selon

l'altitude

Calorifique
Calorifique

й

й

й

й

й

й
й

5"

(1.25kPa)

3.8"

(0.95kPa)

1.1"

(0.27kPa)

#37

DMS

0-4500

ft/pi

(0-1372 m)

WC/C.E.
WC/C.E.
WC/C.E.

15,500

Btu/h

(4.54 kW)

30,000

Btu/h

(8.79 kW)

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United
States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owner's manual
for details.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces
normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles.

This vented gas fireplace heater is not for use with air filters.

Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.

Fan (Part # 432-917) Optional Bay Window (Part #510-930) Option: HeatWave Kit # 946-556

Electrical supply / Électrique 115VAC, 1.13 A, 60Hz.

Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements
locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.

Made in Canada/

Fabrique au Canada

FPI Fireplace Products International Ltd.Delta, BC, Canada

Listed:
Certified for/Certifi e pour:
Tested to:
WN# 16444

CANADA and U.S.A.

CGA-2-17-M91, ANSI Z21.88a-2007 / CSA 2.33a-2007

VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION

é

VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS.

NE PAS UTILISER AVEC DUCOMBUSTIBLE SOLIDE.

FOYER AU GAZ À ÉVACUATION -

SAFETY LABEL

For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfi tter licensed in the Commonwealth of
Massachusetts.

For the State of Massachusetts, fl exible
connectors shall not exceed 36 inches in
length.

For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.

The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.