beautypg.com

Installation, Clearances – Regency Panorama P36 Medium Gas Fireplace User Manual

Page 11

background image

FPI P36-4 Zero Clearance Direct Vent Gas Fireplace

11

INSTALLATION

The clearances listed below are Minimum distances unless otherwise stated:

A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest
importance that this fi replace and vent system be installed only in accordance with these instructions.

Clearance to Combustibles from:
Back

0"

(0mm)

Side

0"

(0mm)

Floor

0"

(0mm)

NOTE: The minimum fl oor clearance must be maintained from the top surface of the carpeting, tile, etc.

Minimum Clearance from Top of Unit to:
Ceiling

from top of unit.

32"

(1016mm)

Flush

Front

6"*

(152mm)

Full Screen Doors

6"*

(152mm)


* Measured from Surround or Front. See the "Regency Clearances for dimensions" section.

Horizontal Vent Clearances:
Top

2"

(51mm)

Side

1-1/2"

(38mm)

Bottom

1-1/2"

(38mm)

Vertical Vent Clearances

1-1/4"

(32mm)

Alcove Clearances**:
Max.

Depth

36"

(914mm)

Min.

Width

48"

(1219mm)

Min.

Height

72"

(1829mm)

WARNING: Fire hazard is an extreme risk if these clearances are not adhered to.

The HeatWave Duct Kit and the Heat
Release Kit have different clearance
and framing requirements, check the
HeatWave and Heat Release manual
for details.

Heat Release Kit

CLEARANCES