Operating instructions, Aeration adjustment, Normal operating sounds of gas appliances – Regency Panorama P36 Medium Gas Fireplace User Manual
Page 48: Shutdown procedure, First fire, Lighting procedure
48
FPI P36-4 Zero Clearance Direct Vent Gas Fireplace
48
OPERATING INSTRUCTIONS
During the fi rst few fi res, a white fi lm
may develop on the glass front as part
of the curing process. The glass should
be cleaned or the fi lm will bake on and
become very diffi cult to remove. Use a
non-abrasive cleaner and NEVER clean
the glass while it is hot.
AERATION
ADJUSTMENT
The air shutter can be adjusted by moving the
adjusting wire up or down. The wire is accessed
through the bottom louver opening. Open the air
shutter for a blue fl ame or close for a yellower
fl ame. The burner aeration is factory set but
may need adjusting due to either the local gas
supply or altitude.
Minimum Air Shutter Opening:
3/16"
Natural
Gas
1/2"
Propane
CAUTION: Carbon will be produced if air shutter
is closed too much.
Note: Any damage due to carboning resulting
from improperly setting the aeration
controls is NOT covered under warranty.
Note: Aeration Adjustment should only be
performed by an authorized FPI Installer
at the time of installation or service.
NORMAL OPERATING
SOUNDS OF GAS
APPLIANCES
It is possible that you will hear some sounds
from your gas appliance. This is perfectly normal
due to the fact that there are various gauges
and types of steel used within your appliance.
Listed below are some examples. All are normal
operating sounds and should not be considered
as defects in your appliance.
Blower:
FPI gas appliances use high tech blowers to
push heated air farther into the room. It is not
unusual for the fan to make a "whirring" sound
when ON. This sound will increase or decrease
in volume depending on the speed setting of
your fan speed control.
Burner Tray:
The burner tray is positioned directly under the
burner tube(s) and logs and is made of a different
gauge material from the rest of the fi rebox and
body. Therefore, the varying thicknesses of steel
will expand and contract at slightly different
rates which can cause "ticking" and "cracking"
sounds. You should also be aware that as there
are temperature changes within the unit these
sounds will likely re-occur. Again, this is normal
for steel fi reboxes.
Blower Thermodisc:
When this thermally activated switch turns ON
it will create a small "clicking" sound. This is the
switch contacts closing and is normal.
Pilot Flame:
While the pilot fl ame is on it can make a very
slight "whisper" sound.
Gas Control Valve:
As the gas control valve turns ON and OFF, a
dull clicking sound may be audible, this is normal
operation of a gas regulator or valve.
Unit Body/Firebox:
Different types and thicknesses of steel will
expand and contract at different rates resulting
in some "cracking" and "ticking" sounds will be
heard throughout the cycling process.
IMPORTANT Gas on/off knob cannot be
turned from "PILOT" to "OFF" unless it is
partially depressed.
1) Turn burner OFF using "ON/OFF" switch.
2) Turn gas control knob so indicator points
to "OFF" position and allow 5 minutes for
any gas in the combustion chamber to
escape.
3) Turn gas control knob counterclockwise
so indicator points to the "PILOT" position.
Depress the gas control knob fully. Depress
the igniter button several times until the
pilot lights. After approximately one minute,
release the gas control knob. The pilot fl ame
should continue to burn. If the pilot does not
remain lit, repeat operation allowing a longer
period before releasing gas control knob.
4) When the pilot stays lit, turn the gas knob
further counterclockwise to the "ON"
position.
5) Use the wall switch, thermostat or remote
control to turn on the unit.
6) Rotate
the
fl ame height regulator to adjust
the fl ame height higher or lower.
SHUTDOWN
PROCEDURE
1) Use the wall switch, thermostat or remote
control to turn off the main burner.
2) Turn the main gas control clockwise to the
"OFF" position to turn off the pilot.
3) Turn off all electric power to appliance if
service is to be performed.
FIRST FIRE
The fi rst fi re in your fi replace is part of the
paint curing process. To ensure that the paint
is properly cured, it is recommended that you
burn your fi replace for at least four (4) hours the
fi rst time you use it with the fan on.
When fi rst operated, the unit will release an odour
caused by the curing of the paint, the burning
off of any oils remaining from manufacturing.
Smoke detectors in the house may go off at
this time. Open a few windows to ventilate the
room for a couple of hours.
The glass panel may require cleaning after the
unit has cooled down.
DO NOT ATTEMPT TO CLEAN THE
GLASS WHILE IT IS HOT.
Note: When the glass is cold and the appliance
is lit, it may cause condensation and
fog the glass. This condensation is
normal and will disappear in a few
minutes as the glass heats up.
DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.
IMPORTANT
To ignite or reignite the pilot,
you must fi rst release the ten-
sion springs below the door.
NOTE: For all propane units and units
equipped with electric spark boxes,
see "Copy of Lighting Plate Instruc-
tions" section for more details.
Only when the pilot holds, without pressure
being applied to the control knob, reapply the
tension springs to the door. The unit must not be
operated with the tension springs unattached.
LIGHTING
PROCEDURE
Adjustment wire: Push to close or
pull to open aeration cap.
Closed - Tall yellow
Open - Short Blue