beautypg.com

Maintenance, Log replacement, Thermopile/ thermocouple – Regency Panorama P36 Medium Gas Fireplace User Manual

Page 50: Glass gasket, Door glass

background image

50

FPI P36-4 Zero Clearance Direct Vent Gas Fireplace

MAINTENANCE

3) Check for evidences of excessive

condensation, such as water droplets forming
in the inner liner, and subsequently dripping
out the joints, Continuous condensation can
cause corrosion of caps, pipe, and fi ttings. It
may be caused by having excessive lateral
runs, too many elbows, and exterior portions
of the system being exposed to cold weather.

4) Inspect joints, to verify that no pipe

sections or fi ttings have been disturbed,
and consequently loosened. Also check
mechanical supports such as Wall Straps,
or plumbers' tape for rigidity.

LOG REPLACEMENT

The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door and carefully remove the
logs. (The pilot light generates enough heat to
burn someone.) If for any reason a log should
need replacement, you must use the proper
replacement log. The position of these logs
must be as shown in the diagrams under Log
Installation.

Note: Improper positioning of logs may

create carbon build-up and will
severely alter the unit's performance
which is not covered under warranty.

THERMOPILE/

THERMOCOUPLE

1) Open the bottom louvers.

2) Loosen the thermocouple or thermopile with

a 7/16" wrench.

3) Disconnect thermocouple by loosening nut

from the valve with a 9mm wrench. Dis-
connect thermopile by loosening 2 screws
marked TP on the valve.

4) Drop the thermocouple or thermopile down

from the bracket and pull it out of the unit.

5) Reinstall the new ones in reverse order.

GLASS GASKET


If the glass gasket requires replacement use
5/8" fl at glass gasket for the Bay Front (Part
# 936-243) and a tadpole glass gasket for the
Flush Front (Part # 936-155).

DOOR GLASS

Your FPI fi replace is supplied with high tem-
perature, 5 mm Neoceram ceramic glass that
will withstand the highest heat that your unit will
produce. If your glass requires cleaning, we
recommend using an approved glass cleaner
available at all authorized dealers. Do not use
abrasive materials. Do not clean the glass
when hot.

In the event that you break your glass by impact,
purchase your replacement from an authorized
FPI dealer only, and follow our step-by-step
instructions for replacement.

WARNING: Do not operate the appli-
ance with the glass panels removed,
cracked or broken. Replacement of
the glass panels should be done
by a licensed or qualifi ed service
person.

CAUTION: Wear gloves when
removing damaged or broken
glass.

FLUSH GLASS REPLACEMENT

Remove the fl ush door front, see the "Stand-
ard Flush Door" section. Remove the 4 glass
clips from each corner. Slide in the new
replacement glass. Push the 4 glass clips
back onto the frame. The glass must have
gasketing around it.