beautypg.com

Installation, V1 v h – Regency Panorama P36 Medium Gas Fireplace User Manual

Page 25

background image

FPI P36-4 Zero Clearance Direct Vent Gas Fireplace

25

INSTALLATION

Vertical Venting with Two (2) 90

o

Elbows

Vertical Venting with Three (3) 90

o

Elbows

One 90

o

elbow = Two 45

o

elbows.

V1

V

H

V

H1

H

V1

One 90

o

elbow = Two 45

o

elbows.

Option

V

H

V + V1

With these options,
max. total pipe length
is 30 feet with min.
of 6 feet total vertical
and max. 8 feet total
horizontal.

Please note min. 1
foot between 90

o

elbows is required.

A)

0' Min.

2' Max.

1' Min.

B)

1' Min.

4' Max.

2' Min.

C)

2' Min.

5' Max.

3' Min.

D)

3' Min.

6' Max.

4' Min.

E)

4' Min.

7' Max.

5' Min.

F)

5' Min.

8' Max.

6' Min.

Lengths do not include elbow indicated

For additional vertical venting with 2 x 90

o

elbows, refer to next page.

Option

V

H + H1

V + V1

With these options,
max. total pipe length
is 30 feet with min. of
10 feet total vertical
and max. 8 feet total
horizontal.

Please note min. 1
foot between 90

o

elbows is required.

A)

0' Min.

2' Max.

2' Min.

B)

1' Min.

2' Max

3' Min.

C)

2' Min.

3' Max

4' Min.

D)

3' Min.

4' Max

6' Min.

E)

4' Min.

5' Max

7' Min.

F)

5' Min.

6' Max

8' Min.

G)

6' Min.

7' Max

9' Min.

H)

7' Min.

8' Max

10' Min.

Lengths do not include elbow indicated