Installation – Regency Panorama P36 Medium Gas Fireplace User Manual
Page 37
FPI P36-4 Zero Clearance Direct Vent Gas Fireplace
37
INSTALLATION
27) Run the other end of the ground wire
and DC spark generator wires through
the bushing on the heat shield.
29) Plug the DC spark generator wires to the
DC Sparker.
30) Connect the ground wire to the DC Sparker
mounting bracket.
Heat Shield
33) Find a location which is not too hot and
is easy to reach for changing the battery.
Note: It should be kept away from the
chain.
34) Tie up the loose wires with the wire clip.
Chain
35) Check for gas leaks.
36) Check inlet and outlet pressures.
37) Check operation of fl ame control.
38) Check for proper fl ame appearance and
glow on logs.
NOTE: The battery in the DC Sparker
Box will need to be replaced an-
nually.
25) Locate the ground lug.
26) Connect one end of the supplied green
ground wire to the lug with the nut and
washer from the kit.
Ground
wire from
kit
28) Install the 1/2" bushing to the heat
shield.
32) Mount the heat shield to the DC Sparker.
Secure into place with the velcro, which is
provided in the kit.
For P36D-1 / P36-4 Only:
25a) By the receptical box, left of the unit.
For U32-5 Only:
25b) Located on the left side of the unit.
31) Install the supplied battery into the DC
Sparker Box by opening the battery
compartment.
Battery
Compartment