Installation – Regency Panorama P36 Medium Gas Fireplace User Manual
Page 30
30
FPI P36-4 Zero Clearance Direct Vent Gas Fireplace
INSTALLATION
Diagram 4
be pointing up. Insure that the 1-1/2"
clearances to combustible materials
are maintained (Diagram 4). Install the
termination cap.
The four wood screws provided should
be replaced with appropriate fasteners for
stucco, brick, concrete, or other types of
sidings.
Note: If installing termination on a siding
NOTE: For Snorkel terminations in ABOVE
grade installations, follow national
or local code requirements.
If the Snorkel Termination must be installed
below grade, i.e. basement application, proper
drainage must be provided to prevent water
from entering the Snorkel Termination. Refer
to Diagram 4. Do not attempt to enclose the
Snorkel within the wall, or any other type of
enclosure.
6) The arrow on the vent cap should
*Diagrams 3 & 4: As specifi ed in CGA B149
Installation Code. Local codes or regulations
may require different clearances.
DURA-VENT HORIZONTAL
TERMINATIONS
Install the vent system according to the
manufacturer's instructions included with
the components.
1) Set the unit in its desired location. Check
to determine if wall studs or roof rafters
are in the way when the venting system is
attached. If this is the case, you may want
to adjust the location of the unit. Rough in
the gas preferably on the right side of the
unit and the electrical (junction block is on
the left side) on the left.
2) Direct Vent pipe and fi ttings are designed
with special twist-lock connections to con-
nect the venting system to the appliance
fl ue outlet. A twist-lock appliance adaptor
is an available option that must be used in
conjunction with the Simpson Dura-Vent
Direct Vent system.
3) Put a bead of silicone inside the outer
section of the adapter and a bead of Stove
Mate on the inner collar. Slip the adapter
over the existing inner and outer fl ue collar
and fasten to the outer collar only with the
3 supplied screws (drilling pilot holes will
make this easier). Level the fi replace and
fasten it to the framing using nails or screws
through the nailing strips.
4) Assemble the desired combination of pipe
and elbows to the appliance adaptor and
twist-lock for a solid connection.
Note: a) Twist-lock procedure: Four indenta-
tions, located on the female ends of
pipes and fi ttings, are designed to slide
straight onto the male ends of adjacent
pipes and fi ttings, by orienting the four
pipe indentations so they match and
slide in to the four entry slots on the male
ends, Diagram 1. Push the pipe sections
completely together, then twist-lock
one section clockwise approximately
one-quarter turn, until the two sections
are fully locked. The female locking lugs
will not be visible from the outside, on
the Black Pipe or fi ttings. They may be
located by examining the inside of the
female ends.
Diagram 1
b) Horizontal runs of vent must be
supported every three feet. Wall straps
are available for this purpose.
5) Mark the wall for a 10" x 10" square hole. The
center of the square hole should line up with
the centerline of the horizontal pipe. Cut and
frame the 10 inch square hole in the exterior
wall where the vent will be terminated. If the
wall being penetrated is constructed of non-
combustible material, i.e. masonry block or
concrete, a 7"(178mm) dia. (7-1/2"(191mm)
dia. for fl ex) hole is acceptable.
Diagram 2
Note:
a) The horizontal run of vent must be level,
or have a 1/4 inch rise for every 1 foot
of run towards the termination. Never
allow the vent to run downward. This
could cause high temperatures and may
present the possibility of a fi re.
b) The location of the horizontal vent
termination on an exterior wall must meet
all local and national building codes, and
must not be blocked or obstructed. For
External Vent Terminal Locations, see
the "Exterior Vent Termination Locations"
section.
c) Snorkel Terminations:
For
installations
requir-
ing a vertical rise on the
exterior of the building,
14-inch and 36-inch tall
Snorkel Termi-
nations are
available, as
well as the
s t a n d a r d
Riser Vent.
Follow the
s a m e i n -
s t a l l a t i o n
procedures
as used for
s t a n d a r d
Horizontal
Te r m i n a -
tion. NEV-
ER install
the snorkel upside down.
Below Grade Installation
Diagram 3a
Note: Riser Vent
is only for use
in above grade
terminations.
NOTE: For best results and optimum perform-
ance with each approved venting system, it is
highly recommended to apply “Mill-Pac” seal-
ant (supplied) to every inner pipe connection.
Failure to do so may result in drafting or per-
formance issues not covered under warranty.
Silicone (red RTV) is optional.
Note: With Dura-
Vent, the minimum
height is achieved
by installing a 90
o
elbow directly to
the fl ue adaptor.