beautypg.com

Maintenance, Valve assembly replacement – Regency Horizon HZI234E Small Gas Insert User Manual

Page 44

background image

44

Regency

®

HZI234E Direct Vent Gas Insert

MAINTENANCE

1) Shut off gas supply to unit and unplug the

power source by disconnecting the batteries.

2) Open the left and right side faceplate panels.

Contour/Contemporary or remove front low
profi le faceplate.

3) Remove the bottom louver by pulling out.

4) Disconnect the EV1, EV2, and ground wires

from the valve - as shown below.

5) Remove the glass door.

a) Pull off the left side spring hook that holds
the door in place. While holding the hook turn it
upside down and place it into the middle opening
on the top side mounting bracket. Repeat for
right side

.

b)

Swing the door out 45 degrees and lift up

and out.

6) Remove the crystals.

7) Remove panels, if installed.

8) Lift out the bottom tray.

Spring Hook

Top Mounting Bracket

9) Remove the burner by removing 3 screws.

10) Slide burner forward and lift up and out.

11) Remove 15 screws to remove valve assembly

tray.

VALVE ASSEMBLY REPLACEMENT

12) Pull out Valve assembly tray.

13) Disconnect the inlet gas line.

13) Replace valve and gasket (if required).

EV1

EV2

Ground

14) Reverse steps to reinstall.