Warning – Bryant SERIES A 355CAV User Manual

Page 26

background image

26

115-V

FIELD-SUPPLIED

DISCONNECT

SWITCH

115-V

SINGLE

PHASE

AUXILIARY

J-BOX

FURNACE

CONTROL

CENTER

TWO WIRE

24-V

TERMINAL

BLOCK

THREE-WIRE

HEATING

ONLY

FIVE

WIRE

NOTE 5

NOTE 1

NOTE

3

THERMOSTAT

TERMINALS

FIELD-SUPPLIED

DISCONNECT

CONDENSING

UNIT

R

W2

W

C

R

G

Y

GND

GND

GND

GND

FIELD 24-V WIRING

FIELD 115-, 208/230-, 460-V WIRING

FACTORY 24-V WIRING

FACTORY 115-, 208/230-, 460-V WIRING

208/230- OR

460-V

THREE PHASE

208/230-V

SINGLE

PHASE

W/W1

Y/Y2

G

C

NOTES:

1.

2.

3.

4.

5.

Connect Y or Y/Y2 terminal as shown for proper cooling operation.

Proper polarity must be maintained for 115-v wiring.

Use W2 with 2-stage thermostat when zoning.

If any of the original wire, as supplied, must be replaced, use

same type or equivalent wire.

Some thermostats require a "C" terminal connection as shown.

A98325

Fig. 29 -- Heating and Cooling Application Wiring Diagram

Table 4 – Electrical Data

UNIT SIZE

VOLTS---

HERTZ---

PHASE

OPERATING VOLTAGE

RANGE

MAXIMUM

UNIT

AMPS

MINIMUM

WIRE SIZE

MAXIMUM

WIRE

LENGTH

FT (M)}

MAXIMUM

FUSE OR CKT

BKR

AMPS**

Maximum*

Minimum*

060---14/042060

115---60---1

127

104

8.96

14

30 (9.1)

15

080---14/042080

115---60---1

127

104

8.96

14

30 (9.1)

15

080---20/060080

115---60---1

127

104

14.06

12

31 (9.4)

20

100---20/060100

115---60---1

127

104

14.06

12

31 (9.4)

20

120---20/060120

115---60---1

127

104

14.06

12

31 (9.4)

20

* Permissible limits of voltage range at which unit will operate satisfactorily.
{

Unit ampacity = 125 percent of largest operating component’s full load amps plus 100 percent of all other potential operating components’ (EAC,

humidifier, etc.) full load amps.
}

Length shown is as measured 1 way along wire path between unit and service panel for maximum 2 percent voltage drop.

** Time---delay type is recommended.

ELECTRICAL SHOCK AND FIRE HAZARD
Failure to follow this warning could result in electrical

shock, fire, or death.
The cabinet MUST have an uninterrupted or unbroken

ground according to NEC ANSI/NFPA 70--2008 and

Canadian Electrical Code CSA C22.1 or local codes to

minimize personal injury if an electrical fault should occur.

This may consist of electrical wire or conduit approved for

electrical ground when installed in accordance with existing

electrical codes. Do not use gas piping as an electrical

ground.

!

WARNING

COPPER

WIRE ONLY

ELECTRIC

DISCONNECT

SWITCH

ALUMINUM

WIRE

A93033

Fig. 30 -- Disconnect Switch and Furnace

Install power entry hole filler plugs (factory--supplied in loose

parts bag) in unused power entry holes. (See Fig. 31.)

355C