Robustel M1000 XP User Guide User Manual
Page 44
Robustel GoRugged M1000 XP User Guide
RT_UG_M1000 XP_v.1.0.0
19.11.2013
43 / 57
Confidential
Management
Item
Description
Default
Synchronize Device
Time with Computer
Synchronize gateway’s RTC to PC’s clock.
The gateway’s current RTC will be showed at bottom right side of the
configurator.
Null
Output Debug info
to Serial Port
Enable to output the gateway’s debug info to serial port. Then you can
use a hyper terminal to receive the debug info.
This function is often used when we need to diagnose the problem of
the gateway.
Note: This function will take effect immediately after you enable it.
Disable
Upgrade
Upgrade the firmware of gateway via serial port or TCP connection.
The upgrade steps are as bellow:
1. Click “load” button and select the FW file in your computer;
2. Click “Start” button to get started, then you can see a process bar;
3. The updating will last for several minutes, after that you will see a
pop window to indicate the updating is successful.