Robustel M1000 XP User Guide User Manual
Page 29

Robustel GoRugged M1000 XP User Guide
 
RT_UG_M1000 XP_v.1.0.0 
19.11.2013
28 / 57
Confidential
Connection
Item
Description
Default
Mode
@
Socket 
Application 
Selected from “TCP Client”, “TCP Server” and “UDP”. 
TCP Client: Gateway works as TCP client, initiate TCP connection to TCP server, the server 
address supports both IP and domain name. 
TCP Server: Gateway works as TCP server, listening for connection request from TCP 
client. 
UDP: Gateway works as UDP client. 
TCP 
Server 
Address @ 
Socket 
Application 
When gateway works as TCP client, user should input peer TCP server’s IP or domain in 
this item. 
When gateway works as TCP server, this item is unavailable. 
When gateway works as UDP client, user should input peer UDP server’s IP or domain in 
this item. 
null
Port
When gateway works as TCP client, user should input peer TCP server’s port in this item. 
When gateway works as TCP server, user should input TCP server’s listening port in this 
9999