13 reboot, Reboot – Robustel M1000 XP User Guide User Manual
Page 37
Robustel GoRugged M1000 XP User Guide
RT_UG_M1000 XP_v.1.0.0
19.11.2013
36 / 57
Confidential
SMS
Tick the SMS checkbox to allow gateway automatic connects to
GPRS/UMTS with incoming specified short message from specified
Caller ID (phone number).
Specified short message is set at Password item. (e.g. GPRS on)
Disable
Phone Group @ SMS
Set the Phone Group which was allowed to wake up the gateway by
SMS.
1
Password
The specified short message which was used to wake up the gateway
Null
Enable SMS Reply@
SMS
Tick Enable SMS Reply to allow gateway to send reply short message
after automatic connects to GPRS/UMTS by SMS Wakeup from
specified Caller ID (e.g. GPRS on ok!).
Note: Only support text format SMS.
Disable
Serial Data
Tick Enable to allow gateway automatic connects to GPRS/UMTS from
idle mode when there is data (any data) come out from serial port.
After gateway has connected to GPRS/UMTS and established TCP
connection, the “triggered” data will be sent to destination site.
Enable
Shut Down Module
When Idle
Enable to set the gateway to shut down module when connectivity is
in idle status. This function only can be configured under Connect On
Demand mode.
Disable
Note:
1. Time format for Time reboot is 24-hours.
2. The phone numbers for Call and SMS function can be set in Phone Book tab.
3. In some countries, the Caller ID is required to be written in international format, starting with “+” followed by the
country code.
3.13 Reboot
Since cellular network is not as stable as fixed line, M1000 XP supports various auto reboot function to keep gateway
working 24x7 without hang up.