beautypg.com

Robustel M1000 XP User Guide User Manual

Page 21

background image

Robustel GoRugged M1000 XP User Guide


RT_UG_M1000 XP_v.1.0.0

19.11.2013

20 / 57

Confidential

4.

Go to tab “Settings” -> “Communication”.

2.

Select “TCP” interface and the correct mode in the drop down boxes, and enter the local TCP port. If you choose
client mode, you need to enter the remote gateway’s IP address. Then click “OK”.

Note:
If you choose TCP client mode, the configurator will establish a TCP connection to the remote gateway

which works as TCP server.

If you choose TCP server mode, the configurator will be in listening status. Then you need to send an SMS to

the remote gateway to trigger it to establish a TCP connection with configurator. The form of the SMS is :
“nms, configurator’s IP address, configurator’s TCP port” For example, nms 120.12.23.45 50000.

The NMS function of gateway must have been enabled. Please refer to section 3.16 NMS
The cell phone’s number must be included in gateway’s phonebook.