item.
When gateway works as UDP client, user should input peer UDP server’s port in this item.

Advanced @
Socket
Application

Click to set advanced settings of “Socket Application”.

null

Idle Time

Whether gateway is set as TCP Client or TCP Server, keepalive feature can be used to
detect whether TCP connection is disconnected by sending specific packets in the
transport layer.
User can set idle timeout interval in this item, gateway will send out keepalive packet if
there is no data for more than “Idle Time”. “Idle Time” ranges from 60 to 7200 seconds.

180

Interval

Gateway will re-send the keepalive packet with this interval timeout when it doesn’t
receive respond packets. “Interval” ranges from 10 to 180 seconds.

30

Max Retries

If gateway re-sends keepalive packet continuously for Max Retries times and doesn’t
receive correct respond packets, it will detect that the TCP connection is disconnected
and it try to establish TCP connection again. “Max Retries” ranges from 3 to 10.

3

Max
Connection

When gateway is set as TCP Server, it will wait for TCP connection from TCP Client site.
If TCP connection from TCP Client reaches to “Max Connection” it will drop a new TCP
connection request. “Max Connection” ranges from 1 to 3.

1

Always
Accept New
Connection

After click to enable this item, M1000 XP will always accept new TCP connection and
drop the earliest one at the same time.

Disable

Mode

@

Connection
Control

Select from “Always Online” and “Connect On Demand”.
Always Online: Gateway will automatically initiate a GPRS/UMTS connection after power
on and each restarts, this will remain and will be re-established after an interruption.
Connect On Demand: After select this option, user could configure wakeup at preset
time, wakeup by Call, wakeup by SMS, wakeup by local serial port data at Wakeup Tab.

Connect
On
Demand

Inactivity
Time

User could configure this field after setting gateway under Connect On Demand mode,
input from 10 to 1200 seconds.
This field specifies the idle time setting for GPRS/UMTS auto-disconnection.

120

Connect
Interval

Gateway will automatically re-connect with this interval when it fails communicating to
peer via TCP or UDP; also gateway will automatically re-dial with this interval if PPP dial
up failed. Input from 10 to 1200 seconds.

60

Max Retries
@
Connection
Control

The maximum retries times for automatically re-connect when gateway fails to dial up,
input from 1 to 60.
After maximum retries, gateway will reboot the wireless module.
When connecting successful, the Max Retries counter will be set to 0.

5

Online
Notify

Click to enable Online SMS Notification function, which will send SMS to the phone
numbers included in the Phone Group in this tab.
Online SMS Notification includes follow information:
Name:
Reg:
RSSI:
Operator:

Disable