beautypg.com

Robustel R3000 NU User Manual

Page 10

background image

Robustel GoRugged R3000 NU User Guide


RT_UG_R3000 NU_v.1.0.0 24.03.2014 9 / 110
Confidential

Serial Interface

Number of Ports: 1 x RS-232, 1 x RS-485 or 2 x RS232 or 2 x RS485

ESD Protection: ±15KV

Parameters: 8E1, 8O1, 8N1, 8N2, 7E2, 7O2, 7N2, 7E1

Baud Rate: 300bps to 230400bps

RS-232: TxD, RxD, RTS, CTS, GND

RS-485: Data+ (A), Data- (B), GND

Interface: 3.5mm terminal block with lock


Digital Input

Type: 2 x DI, Dry Contact

Dry Contact: On: open, Off: short to GND

Isolation: 3K VDC or 2K Vrms

Digital Filtering Time Interval: Software selectable

Interface: 3.5mm terminal block with lock

Digital Output

Type: 2 x DO, Sink

Isolation: 3K VDC or 2K Vrms

Absolute Maximum VDC: 36V

Absolute Maximum ADC: 50mA

Interface: 3.5mm terminal block with lock


System

LED Indicators: RUN, WLAN, USR

Built-in RTC, Watchdog, Timer

Expansion: 1 x USB 2.0 host up to 480 Mbps

Storage: 1 x MicroSD


Software

Network protocols: PPPoE, TCP, UDP, DHCP, ICMP, NAT, DMZ, RIP v1/v2, OSPF, DDNS, VRRP, HTTP, HTTPs, DNS, ARP,

QoS, SNTP, Telnet, VLAN, etc