Retsch SK 100 User Manual
Page 19

05/04/2012
Retsch GmbH
19
0002
Necessary tests
Every six months the limit switches and the motor brake should be
checked with proper regard to.
SK 100 standard
Limit switch to the left on the door hinge
*
With an opening gap of 3mm max. the limit switch must cause
the motor to cut out
SK 100 comfort
Limit switch to the left on the door hinge
*
With an opening gap of 3mm max. the limit switch must cause
the motor to cut out
Limit switch to the right on quick-acting closure
*
When the handwheel is turned a maximum of 45° the motor
brake must be activated.
Motor brake
*
Start SK 100
*
Stop SK 100
*
Measure the braking time using a stopwatch
*
Should the braking time exceed 0.5 seconds, contact the ser-
vice technicians
Accessories
*
Base frame
*
Collecting vessel 30l
*
Filter hose for 30l vessel
*
Stand for DR 100/75 vibratory feeder
*
DR 100/75 vibratory feeder
*
Dirt collecting pan of plastic
*
Conidur bottom sieve from 0.12 to 2.0mm
*
Round hole bottom sieves 3.0 to 10mm
Copyright
It is not allowed to pass on or duplicate this documentation, to use or pass
on its content without the permission of Retsch GmbH. Any infringement
will be subject to compensation.
Changes
We reserve the right to make technical changes.