Set target high resolution, Set target low resolution forward – Pololu Jrk USB User Manual
Page 32

This command will turn the motor off by setting the Awaiting Command error bit. The jrk will not restart the motor
until it receives a Set Target command. The jrk can be configured to either brake or coast while the motor is off
(
).
Set Target High Resolution
Compact protocol, binary: 110LLLLL, 0HHHHHHH
Compact protocol, hex: 0xC0 + target low 5 bits, target high 7 bits
Pololu protocol, binary: 10101010, device number, 010LLLLL, 0HHHHHHH
Pololu protocol, hex: 0xAA, device number, 0x40 + target low 5 bits, target high 7 bits
(where target is the 12-bit number HHHHHHHLLLLL)
This command clears the Awaiting Command error bit and (if Input Mode is Serial) lets you set the 12-bit target to
any of its allowed values (0–4095). The meaning of the target depends on what Feedback Mode the jrk is in (
). The lower 5 bits of the command byte represent the lower 5 bits of the target, while the lower 7 bits of the data
byte represent the upper 7 bits of the target.
For example, if you want to set the target to 3229 (
1100100
11101
in binary), you could send the following byte
sequence:
in binary: 110
11101
, 0
1100100
in hex: 0xDD, 0x64
in decimal: 221, 100
Here is some example C code that will generate the correct serial bytes, given an integer “target” that holds the desired
target (0–4095) and an array called serialBytes:
serialBytes[0] = 0xC0 + (target & 0x1F); // Command byte holds the lower 5 bits of target.
serialBytes[1] = (target >> 5) & 0x7F; // Data byte holds the upper 7 bits of target.
Many motor control applications do not need 12 bits of target resolution. If you want a simpler and lower-resolution
set of commands for setting the target, you can use the Set Target Low Resolution commands. Alternatively, you
could use the Set Target High Resolution command with the lower 5 bits of the target always zero: sending a 0xC0
byte followed by a data byte (0–127) will result in setting the target to a value of 32 multiplied by the data byte.
Set Target Low Resolution Forward
Compact protocol: 0xE1, magnitude
Pololu protocol: 0xAA, device number, 0x61, magnitude
This command clears the Awaiting Command error bit and (if Input Mode is Serial) sets the target to a value of 2048
or greater which is determined by the magnitude (0–127).
If the Feedback Mode is Analog or Tachometer, then the formula is
Target = 2048 + 16×magnitude.
If the Feedback Mode is None (speed control mode), then the formula is
Target = 2048 + (600/127)×magnitude.
This means that a magnitude of 127 will set the duty cycle target to full-speed forward (+600), while a magnitude of
zero will make the motor stop.