beautypg.com

Connection to a net2 acu reader port – Paxton SONY number plate reader User Manual

Page 2

background image

Page 2

WARNING: There is no mains power

switch on the unit. Ensure that the mains

supply is turned off before working on

any part of the power supply of this unit.

115/230V AC power connection

Connect the AC mains

supply with Earth wire to

the terminal block

The supplied housing is a Videotec HOV. Detailed drawings are available on the back page.

HOV details:

http://www.videotec.com/en/page_114.html

Brackets:

http://www.videotec.com/en/page_267.html

INSTALLATION - Mounting brackets and hardware

Low voltage (12V DC) connection

If required, the camera system (without the condensation heater)

may be directly powered from a 1A / 12V DC feed.

Unplug the connection to the Heater. Remove the two screws

holding the connection board and the two screws holding the

power supply module. Lift these assemblies clear of the housing.

The Brown (0v) and White (12V) connections can then be

removed from the power supply terminal block.

Connect the 12V DC feed to these wires.

Ensure that the polarity is correct before powering up the unit. Incorrect wiring

may cause irreversible damage to the 12V / 5V regulator circuit.

Two mounting points are provided.

- Lateral - 2 x M5 bolts at 70 mm spacing

- Rectangular (with cable exit) - 4 x M5 bolts. 40 mm x 62 mm.

Connection to a Net2 ACU reader port

The data connection to the Net2 ACU only requires

the following signals.

DATA 0

Net2 - Yellow

DATA 1

Net2 - Blue

GND/0V

Net2 - Black

Depress the white button on the connection block to

open the terminal and release it to grip the wire.

Connect the data cable to the Net2 ACU reader port.

WARNING: The lid section of the case is much heavier than the base. Take care when carrying

or mounting the unit with the lid open that the unit is fully supported or it could overbalance !!