beautypg.com

Nitrogen tetroxide service – Orbital Minotaur VI User Manual

Page 104

background image

Minotaur IV • V • VI User’s Guide

Section 8.0 – Optional Enhanced Capabilities

necessary) and fuel transfer cart, and all personnel required to conduct fuel loading operations.
Emergency unloading operations can also be supported if desired. Figure 8.15-2 shows hardware used
by UPC for hydrazine servicing.

Figure 8.15-2. UPC Provides Reliable and Demonstrated Hydrazine Servicing for Minotaur


8.16. Nitrogen Tetroxide Service

Under this enhancement, Orbital provides Nitrogen Tetroxide (NTO) loading service for the SV though a
contract to UPC. The scope of this enhancement includes the procurement of NTO, the preparation of
documentation for loading operations, the support of safety and integrated operations meetings, the
provision of equipment needed for SCAPE operation, including personal protection equipment (if
necessary) and NTO transfer cart, and all personnel required to conduct fuel loading operations.
Emergency unloading operations can also be supported if desired.

Release 2.0

June 2013

89